RPC-6022GW Rackmount LCD Workstation Page 1
RPC-6022GW Rackmount LCD Workstation Revision MODEL RPC-6022GW Rackmount LCD Workstation Revision Number Description Date of Issue 1.
RPC-6022GW Rackmount LCD Workstation Copyright COPYRIGHT NOTICE The information in this document is subject to change without prior notice in order to improve reliability, design and function and does not represent a commitment on the part of the manufacturer. In no event will the manufacturer be liable for direct, indirect, special, incidental, or consequential damages arising out of the use or inability to use the product or documentation, even if advised of the possibility of such damages.
RPC-6022GW Rackmount LCD Workstation Packing List NOTE: If any of the components listed in the checklist below are missing, please do not proceed with the installation. Contact the IEI reseller or vendor you purchased the RPC-6022GW Rackmount LCD Workstation from or contact an IEI sales representative directly. To contact an IEI sales representative, please send an email to sales@iei.com.tw. The items listed below should all be included in the RPC-6022GW Rackmount LCD Workstation package.
RPC-6022GW Rackmount LCD Workstation Table of Contents 1 INTRODUCTION....................................................................................................11 1.1 RPC-6022GW OVERVIEW ....................................................................................... 12 1.2 RPC-6022GW FEATURES ........................................................................................ 12 1.3 MODEL VARIATIONS ......................................................................................
RPC-6022GW Rackmount LCD Workstation 4.2.3 Packing List ..................................................................................................... 34 4.3 PRE-INSTALLATION PREPARATION ............................................................................ 37 4.3.1 System Planning............................................................................................... 37 4.3.2 Tools ..........................................................................................................
RPC-6022GW Rackmount LCD Workstation 6.1 USER MODE OSD STRUCTURE ................................................................................ 78 6.1.1 OSD Buttons..................................................................................................... 78 6.1.2 OSD Menu Structure ........................................................................................ 79 6.2 USING THE OSD.......................................................................................................
RPC-6022GW Rackmount LCD Workstation List of Figures Figure 2-1: RPC-6022GW Front Panel (External) .....................................................16 Figure 2-2: RPC-6022GW Front Panel (Internal) ......................................................17 Figure 2-3: RPC-6022GW 14-Slot Rear Panel ...........................................................18 Figure 2-4: RPC-6022GW Motherboard Rear Panel .................................................19 Figure 2-5: RPC-6022GW Top Panel...................
RPC-6022GW Rackmount LCD Workstation Figure 4-20: Install Workstation into Rack ...............................................................62 Figure 5-1: PSU External Retention Screws.............................................................68 Figure 5-2: PSU Internal Retention Screws ..............................................................69 Figure 5-3: System Fan Retention Screws ...............................................................70 Figure 5-4: Disconnect the Cooling Fan .........
RPC-6022GW Rackmount LCD Workstation List of Tables Table 1-1: RPC-6022GW Model Options ...................................................................13 Table 2-1: General Physical Dimensions ..................................................................23 Table 3-1: RPC-6022GW Specifications ....................................................................26 Table 3-2: LCD Specifications....................................................................................
RPC-6022GW Rackmount LCD Workstation Chapter 1 1 Introduction Page 11
RPC-6022GW Rackmount LCD Workstation 1.1 RPC-6022GW Overview The RPC-6022GW is a PC/AT compatible computer designed for industrial applications. It has a rugged steel chassis specially designed to work under harsh environmental conditions while also being highly reliable. The RPC-6022GW features 14-slot passive backplanes and a full line of dependable AC/DC power supplies. Models supporting ATX motherboards feature seven expansion slots.
RPC-6022GW Rackmount LCD Workstation Table 1-1 shows the available options.
RPC-6022GW Rackmount LCD Workstation THIS PAGE IS INTENTIONALLY LEFT BLANK Page 14
RPC-6022GW Rackmount LCD Workstation Chapter 2 2 Mechanical Overview Page 15
RPC-6022GW Rackmount LCD Workstation 2.1 External Overview The following sections describe the physical layout of the RPC-6022GW Rackmount LCD Workstation. 2.1.1 Front Panel The RPC-6022GW Rackmount LCD Workstation has the following front panel items: Heavy duty steel front panel 12.1” Flat panel TFT LCD screen Full-function membrane keys OSD controller Lockable drive bay access door conceals o o o o o One 5.25” drive bay One 3.
RPC-6022GW Rackmount LCD Workstation Figure 2-2: RPC-6022GW Front Panel (Internal) Page 17
RPC-6022GW Rackmount LCD Workstation 2.1.
RPC-6022GW Rackmount LCD Workstation 2.1.
RPC-6022GW Rackmount LCD Workstation 2.1.
RPC-6022GW Rackmount LCD Workstation 2.1.
RPC-6022GW Rackmount LCD Workstation 2.2 Internal overview Figure 2-7 shows the internal components of the RPC-6022GW LCD workstation.
RPC-6022GW Rackmount LCD Workstation 2.3 Physical Dimensions The following sections describe the physical dimensions of the RPC-6022GW. 2.3.1 General Physical Dimensions General physical dimensions for the RPC-6022GW are shown in Table 2-1.
RPC-6022GW Rackmount LCD Workstation 2.3.2 RPC-6022GW Physical Dimensions The physical dimensions of the RPC-6022GW are shown in Figure 2-8.
RPC-6022GW Rackmount LCD Workstation Chapter 3 3 Detailed Specifications Page 25
RPC-6022GW Rackmount LCD Workstation 3.1 RPC-6022GW Specifications Table 3-1 shows the RPC-6022GW specifications. LCD Type 12.1" TFT Input Interface VGA Max. Resolution 800 x 600 Backlight MTBF 50,000 Hrs Pixel Pitch (mm) 0.
RPC-6022GW Rackmount LCD Workstation 3.2 LCD Specifications Table 3-2 lists the RPC-6022GW LCD specifications. Size 12.1” MFR/Model AU Optronics/G121SN01 Resolution SVGA (800 x 600) Active Area (mm) 246.0(H) x 184.5(V) Pixel Pitch (mm) 0.3075(H) x 0.3075(V) Pixel Arrangement R.G.B. Vertical Stripe Display Mode Normally White Typical White Luminance (cd/m2) 400 Contrast Ratio 500:1 Optical Rise Time/Fall Time (msec) 10/25 Nominal Input Voltage (V) 3.3 Typical Power Consumption (W) 7.
RPC-6022GW Rackmount LCD Workstation 3.3 ACE-832AP PSU Specifications Table 3-3 lists the ACE-832AP power supply specifications. INPUT OUTPUT Voltage 90 ~ 264Vrms Full Range Frequency 50 ~ 60Hz Input 6A(RMS)@115VAC Current 3A(RMS)@230VAC Inrush 60A Max for 115VAC Current 90A Max for 230VAC Voltage Min. Load Max. Load Ripple/Noise +3.3V 0.3A 28A 50mV +5V 0.1A 30A 50mV +12V 0A 15A 120mV -5V 0A 0.3A 100mV -12V 0A 0.8A 120mV +5Vsb 0A 2A 100mV Total Current of +3.
RPC-6022GW Rackmount LCD Workstation 3.4 Recommended IEI Backplanes, Motherboards and PSUs Refer to Appendix B for recommended IEI backplanes and power supply units for the RPC-6022GW rackmount workstation.
RPC-6022GW Rackmount LCD Workstation THIS PAGE IS INTENTIONALLY LEFT BLANK Page 30
RPC-6022GW Rackmount LCD Workstation Chapter 4 4 Installation Page 31
RPC-6022GW Rackmount LCD Workstation 4.1 Installation Considerations 4.1.1 Installation Precautions When installing the RPC-6022GW, please follow the precautions listed below: Read the user manual: The user manual provides a complete description of the RPC-6022GW Rackmount LCD Workstation, installation instructions and configuration options. Turn Off Power: When installing the RPC-6022GW Rackmount LCD Workstation, make sure the power is off.
RPC-6022GW Rackmount LCD Workstation o o Memory modules (DIMMs) CompactFlash® disks Backplane/Motherboard: The backplane or motherboard installed in the RPC-6022GW Rackmount LCD Workstation is separately purchased. Disk Drives: Disk drives installed into the RPC-6022GW Rackmount LCD Workstation are separately purchased. Disk drive support is CPU card dependent. Before purchasing a CPU card or disk drives, please check the CPU card disk drive support. 4.2 Unpacking 4.2.
RPC-6022GW Rackmount LCD Workstation Step 1: Use box cutters, a knife or a sharp pair of scissors to open the top of the external (second) box. Step 2: Open the external (second) box. Step 3: Use box cutters, a knife or a sharp pair of scissors to open the top of the internal (first) box. Step 4: Lift the workstation out of the boxes. Step 5: Remove both polystyrene ends from each side. Step 6: Pull the plastic cover off the workstation.
RPC-6022GW Rackmount LCD Workstation Quantity Description 1 Backplane to SBC connector cable 2 Door key 2 Handle 2 Handle bracket 1 Mini-DIN 6 PS/2 connector cable 1 Power cable Image Page 35
RPC-6022GW Rackmount LCD Workstation Quantity Description 1 Screw kit 7 Short card clamp 1 VGA cable 1 4-pin USB wire cable For Touch Panel (T-R) Models only 1 RS-232 cable 1 TouchKit Driver CD Page 36 Image
RPC-6022GW Rackmount LCD Workstation Quantity 1 Description Image Touch pen Table 4-1: Packing List 4.3 Pre-installation Preparation 4.3.1 System Planning User supplied CPU cards and backplanes or motherboards need to be installed in the system before installing the RPC-6022GW Rackmount LCD Workstation.
RPC-6022GW Rackmount LCD Workstation 4.3.2 Tools Before installing the RPC-6022GW Rackmount LCD Workstation, make sure the following tools are on hand: Phillips (crosshead) screwdriver: All the retention screws on the system are Phillips screws. Soft working mat: When installing the RPC-6022GW Rackmount LCD Workstation, the screen should be placed face down on a soft working mat. 4.4 Installation Procedures 4.4.
RPC-6022GW Rackmount LCD Workstation 4.4.3 Installation Steps Complete the following steps to properly install the workstation: Step 1: Open the top cover. Step 2: Remove the CPU card clamp. Step 3: Remove the disk drive brackets. Step 4: Install the disk drives. Step 5: Reinstall the disk drive bracket with the installed disk drives. Step 6: Install the backplane. Step 7: Install the CPU card. Step 8: Install the PCI or ISA expansion cards (optional). Step 9: Connect all required cables.
RPC-6022GW Rackmount LCD Workstation WARNING: Failure to follow the installation procedures outlined in this section may cause severe damage to the RPC-6022GW Rackmount LCD Workstation. Please follow the installation instructions carefully. 4.5.1 Remove the Top Cover The top cover is secured to the RPC-6022GW Rackmount LCD Workstation with six screws (three each on the left and right panels). To remove the top cover, please follow the steps below.
RPC-6022GW Rackmount LCD Workstation Step 2: Slide the top cover toward the rear panel to remove (Figure 4-2). Step 0: Figure 4-2: Remove the Top Cover from the Chassis 4.5.2 Remove the CPU Card Clamp The CPU card clamp is secured to the RPC-6022GW Rackmount LCD Workstation with two retention screws on the right side of the chassis. To remove the CPU card clamp, please follow the steps below. Step 1: Remove two retention screws that secure the CPU card clamp to the chassis (Figure 4-3).
RPC-6022GW Rackmount LCD Workstation Figure 4-3: CPU Card Clamp Retention Screws Step 2: Detach the power cable that connects the system fan to the power supply unit (Figure 4-4).
RPC-6022GW Rackmount LCD Workstation Step 3: Carefully lift the loose end of the CPU card clamp, and then unhook the other end (Figure 4-5). Figure 4-5: Unhook the CPU Card Clamp Step 4: Remove the CPU card clamp from the chassis.Step 0: 4.5.3 Remove the Drive Bracket The drive bracket is secured to the RPC-6022GW Rackmount LCD Workstation with two retention screws inside the chassis and four outside the chassis. To remove the drive bracket, please follow the steps below.
RPC-6022GW Rackmount LCD Workstation Internal Screws External Screws Figure 4-6: Drive Bracket Retention Screws Step 2: Remove the drive bracket from the chassis.Step 0: 4.5.4 Remove the Drive Slot Blank Plate The drive bracket has one 5.25” and one 3.5” drive slot blank plates. To remove the drive slot blank plates, please follow the steps below. Step 1: Remove the retention screws that secure the drive slot blank plate to the drive bracket (Figure 4-7).
RPC-6022GW Rackmount LCD Workstation Step 2: Remove the drive slot blank plate from the drive bracket.Step 0: 4.5.5 Install Drives The drive bracket supports one 5.25” and three 3.5” disk drives. To install disk drives, follow the instructions below. Step 1: Remove the drive bracket from the RPC-6022GW Rackmount LCD Workstation (see Section 4.5.3). Step 2: Remove the appropriate drive slot blank plate (see Section 4.5.4). Step 3: Slide the disk drive into the drive bracket.
RPC-6022GW Rackmount LCD Workstation 4.5.5.1 3.5” Disk Drive in a 5.25” Slot With the use of IEI’s 3.5” to 5.25” drive adapter bracket, a standard 3.5” disk drive can be installed into a 5.25” drive bay slot. To install a 3.5” hard disk drive into a 5.25” slot of the drive bracket, follow the instructions below. Step 1: Slide a 3.5” disk drive into a 3.5” to 5.25” drive adapter bracket. Make sure the IDE/SATA connector and the power connectors of the drive are facing the rear of the rack.
RPC-6022GW Rackmount LCD Workstation Figure 4-9: 3.5” to 5.25” Drive Adapter Bracket Retention Screws 4.5.6 Reinstall the Drive Brackets After the drives have been installed, reinstall the drive brackets into the chassis. NOTE: It might be easier to connect the disk drive IDE/SATA connectors to the ribbon cables and the disk drive power connectors to the PSU before the drive brackets are reinstalled into the chassis. Step 1: Remount the drive brackets in the original position they were removed from.
RPC-6022GW Rackmount LCD Workstation 4.5.7 Install the Backplane To install a backplane, follow the instructions below. Step 1: Install the correct amount of copper pillars (red circles in Figure 4-10 into the base of the chassis. Depending on the backplane design, the white spacers (blue circles in Figure 4-10) may also have to be installed. NOTE: The backplane shown in Figure 4-10 is an example for reference only. The location and number of copper pillars depends on the backplane being used.
RPC-6022GW Rackmount LCD Workstation Step 2: Mount the backplane into the chassis. Make sure the backplane is positioned so that when the CPU card and PCI/ISA expansion cards are installed, both the CPU card and the PCI/ISA card I/O connectors face the I/O brackets on the rear panel. Step 3: Align the retention screw holes in the backplane with the copper pillars installed in Step 1. Step 4: Insert retention screws to secure the backplane to the chassis (Figure 4-11).
RPC-6022GW Rackmount LCD Workstation 4.5.8 Install the CPU Card CAUTION: Before a CPU card is inserted into the backplane, make sure the CPU card has been correctly prepared and that all the CPU card jumper settings are configured correctly. For CPU card component installation procedures, please refer to the user manual that came with the CPU card.
RPC-6022GW Rackmount LCD Workstation Figure 4-12: Slot Cover Retention Screw and Card Bracket Screws Step 3: Remove the CPU card clamp. (See Section 4.5.2) Step 4: Slide the CPU card into the reserved PCI/ISA socket on the backplane.
RPC-6022GW Rackmount LCD Workstation Figure 4-13: Install the CPU Card Step 5: To secure the CPU card, reinsert the previously removed slot cover retention screw. Step 6: If a PCI/ISA expansion card is not being installed, reinstall the card bracket. Make sure the back edge of the CPU card slides into the guide rails of the card bracket. If a PCI/ISA expansion card is being installed, proceed to the next section.
RPC-6022GW Rackmount LCD Workstation 4.5.9 Install the PCI/ISA Expansion Card To install a PCI expansion card or an ISA expansion card please follow the instructions below. Step 1: Remove the slot cover retention screw to remove the slot bracket from the chassis rear panel (Figure 4-12). Step 2: Remove two card bracket screws to remove the card bracket from the fan bracket (Figure 4-12). Step 3: If necessary, remove the CPU card clamp. (See Section 4.5.
RPC-6022GW Rackmount LCD Workstation Figure 4-14: Installing a Short Card 4.5.11 Connect the Cables The following cables may have to be connected depending on the CPU board and the backplane installed in the system: PSU cables must be connected to the following components (if installed): o o o o o CPU card Backplane FDD HDD Optical drive Disk drive ribbon cables must be connected to the corresponding CPU card disk drive connectors.
RPC-6022GW Rackmount LCD Workstation 4.5.
RPC-6022GW Rackmount LCD Workstation 4.6 Mounting the RPC-6022GW Rackmount Workstation The RPC-6022GW workstation can be mounted to the posts of a standard 19” rack cabinet. Adequate rails, rack tray, or side brackets should also be available for supporting the weight of the workstation. Make sure that all cabling is correctly attached and carefully routed when installing the workstation. NOTE: At least two people are required to mount the workstation.
RPC-6022GW Rackmount LCD Workstation To rack mount the workstation, please follow the steps below. Step 1: The left and right side panels of the workstation each have four screw holes for rack handle bracket installation. Assemble the rack handle brackets and secure them to the workstation.
RPC-6022GW Rackmount LCD Workstation Step 2: Remove the rack slides from the rack slide brackets.
RPC-6022GW Rackmount LCD Workstation Step 3: The left and right side panels of the workstation each have five screw holes for rack slides. Attach one slide section each to the left and right side panel of the workstation.
RPC-6022GW Rackmount LCD Workstation Step 4: Assemble the slide brackets per the manufacturer’s instructions.
RPC-6022GW Rackmount LCD Workstation Step 5: Attach the slide brackets to the rack per the manufacturer’s instructions.
RPC-6022GW Rackmount LCD Workstation Step 6: Insert the workstation with the attached slides into the rack slide brackets until the handle brackets are flush against the rack. (See Figure 4-20) Figure 4-20: Install Workstation into Rack Step 7: If necessary, secure the workstation handle brackets to the rack with the fasteners that came with the workstation.
RPC-6022GW Rackmount LCD Workstation Chapter 5 5 Maintenance Page 63
RPC-6022GW Rackmount LCD Workstation 5.1 Maintenance Overview Maintaining the RPC-6022GW Rackmount LCD Workstation is essential for the smooth operation of system applications. Maintaining the system might mean replacing failed components during the lifetime of the workstation. The following RPC-6022GW components can be replaced. CPU card PCI/ISA expansion card Backplane Power supply unit (PSU) Cooling fans Disk drives o o 3.5” 5.
RPC-6022GW Rackmount LCD Workstation 5.2 CPU Card Replacement To replace a CPU card, please follow the instructions below. Step 1: Turn off and disconnect the workstation from all power sources. Step 2: Remove the workstation from the rack in which it is installed. Step 3: Open the top cover of the RPC-6022GW Rackmount LCD Workstation. (See Section 4.5.1) Step 4: Disconnect all internal and external peripheral device connections from the CPU card. Step 5: Remove the CPU card clamp. (See Section 4.5.
RPC-6022GW Rackmount LCD Workstation 5.3 PCI/ISA Expansion Card Replacement To replace a PCI/ISA expansion card, please follow the instructions below. Step 1: Turn off and disconnect the workstation from all power sources. Step 2: Remove the workstation from the rack in which it is installed. Step 3: Open the top cover of the RPC-6022GW Rackmount LCD Workstation. (See Section 4.5.1) Step 4: Disconnect all internal and external peripheral device connections from the PCI/ISA expansion card.
RPC-6022GW Rackmount LCD Workstation 5.4 Backplane Replacement To replace a backplane, please follow the instructions below. Step 1: Turn off and disconnect the workstation from all power sources. Step 2: Remove the workstation from the rack in which it is installed. Step 3: Open the top cover of the RPC-6022GW Rackmount LCD Workstation. (See Section 4.5.1) Step 4: Remove the CPU card clamp. (See Section 4.5.2) Step 5: Disconnect and remove all CPU cards (see Section 5.
RPC-6022GW Rackmount LCD Workstation 5.5 PSU Replacement To replace a PSU, please follow the instructions below. Step 1: Turn off and disconnect the workstation from all power sources. Step 2: Remove the workstation from the rack in which it is installed. Step 3: Open the top cover of the RPC-6022GW Rackmount LCD Workstation. (See Section 4.5.1) Step 4: Disconnect all the PSU cables from their devices.
RPC-6022GW Rackmount LCD Workstation Step 6: Remove the two internal retention screws that secure the PSU assembly to the right side panel of the workstation (Figure 5-2). Figure 5-2: PSU Internal Retention Screws Step 7: Install the new PSU into the workstation making sure the PSU power connector and PSU cooling fan are facing out of the workstation. Step 8: Reinsert the two previously removed internal retention screws that secure the PSU assembly to the right side panel of the workstation.
RPC-6022GW Rackmount LCD Workstation 5.6 System Fan Replacement To replace the system fan, please follow the instructions below. CAUTION: Carefully note the direction and orientation of the existing system fan prior to replacement. Step 1: Turn off and disconnect the workstation from all power sources. Step 2: Remove the workstation from the rack in which it is installed. Step 3: Open the top cover of the RPC-6022GW Rackmount LCD Workstation. (See Section 4.5.
RPC-6022GW Rackmount LCD Workstation Step 9: Reinstall the CPU card clamp. Step 10: Close the top cover of the workstation and reinstall the workstation into the cabinet or rack in which it was previously installed. Refer to Section 4.6 for complete mounting instructions. Step 0: 5.7 Cooling Fan Replacement To replace a cooling fan, please follow the instructions below. CAUTION: Carefully note the direction and orientation of the existing cooling fan prior to replacement.
RPC-6022GW Rackmount LCD Workstation Step 5: Remove a fan bracket retention screw on each side of the chassis (Figure 5-5 and Figure 5-6). Figure 5-5: Cooling Fan Bracket Retention Screw (Left) Figure 5-6: Cooling Fan Bracket Retention Screw (Right) Step 6: Carefully push the fan bracket toward the rear panel (Figure 5-7).
RPC-6022GW Rackmount LCD Workstation Figure 5-7: Push the Fan Bracket Toward the Rear Panel Step 7: Remove the screws that secure the cooling fan to the fan bracket (Figure 5-8).
RPC-6022GW Rackmount LCD Workstation Step 8: Remove the defective cooling fan. Step 9: Install the new cooling fan to the fan bracket. Secure the fan with retention screws. Step 10: Pull the fan bracket toward the front panel. Step 11: Connect the new cooling fan to the PSU. Step 12: Secure the fan bracket with screws removed earlier. Step 13: Close the top cover of the workstation and reinstall the workstation into the cabinet or rack in which it was previously installed. Refer to Section 4.
RPC-6022GW Rackmount LCD Workstation Step 9: Reconnect all disk drive cabling. Step 10: Close the top cover of the workstation and reinstall the workstation into the cabinet or rack in which it was previously installed. Refer to Section 4.6 for complete mounting instructions. Step 0: 5.8.2 3.5” Disk Drive on a 5.25” Drive Adapter Bracket To replace a 3.5” disk drive on a 5.25” drive adapter bracket, please follow the instructions below. NOTE: Refer to Section 4.5.5.1 for instructions on installing a 3.
RPC-6022GW Rackmount LCD Workstation Step 11: Reconnect all disk drive cabling. Step 12: Close the top cover of the workstation and reinstall the workstation into the cabinet or rack in which it was previously installed. Refer to Section 4.6 for complete mounting instructions.
RPC-6022GW Rackmount LCD Workstation Chapter 6 6 On Screen Display (OSD) Controls Page 77
RPC-6022GW Rackmount LCD Workstation 6.1 User Mode OSD Structure 6.1.1 OSD Buttons There are several on-screen-display (OSD) control buttons on the front panel of the workstation. Table 6-1 shows a typical arrangement of OSD controls. Table 6-1: OSD Control Buttons NOTE: Pressing the direction keys (LEFT or RIGHT) can bring out a simple menu that adjusts the LCD screen brightness and contrast values.
RPC-6022GW Rackmount LCD Workstation 6.1.2 OSD Menu Structure Table 6-2 shows the OSD menu structure. Level 0 Level 1 Value Main Display Features Menu Brightness 0 to 100 Contrast 0 to 100 Horizontal Size 0 to 100 Phase 0 to 100 H. Position 0 to 100 V. Position 0 to 100 Sharpness 1 to 5 Volume This menu is currently disabled, Mute and will be implemented with Speaker models equipped with speakers.
RPC-6022GW Rackmount LCD Workstation Level 0 Level 1 Value Signal Menu Digital Select Analog Backlight Menu Light Enable On or Off Light Contrast 0 to 100 Light Brightness 0 to 100 Light H Start 0 to 100 Light H Width 0 to 100 Light V Start 0 to 100 Light V Height 0 to 100 Table 6-2: OSD Menus 6.2 Using the OSD OSD menu options are described below. 6.2.1 Main Display Features Main display features are shown in Table 6-3.
RPC-6022GW Rackmount LCD Workstation Brightness: The brightness option adjusts the brightness of screen. This function adjusts the offset value of ADC. Setting this value too high or too low will affect the quality of image. Contrast: This function adjusts the gain value of ADC. Adjusting this value too high or too low will worsen the quality of image. Horizontal Size: This item adjusts the screen size in the horizontal direction.
RPC-6022GW Rackmount LCD Workstation 6.2.2 Color Color options are shown in Table 6-4. Table 6-4: Color Options The Color menu fine-tunes the palette of color hues for the LCD. 9300: NTSC standard Kelvin 7500: NTSC standard Kelvin 6500: NTSC standard Kelvin User: This item allows fine-tuning the balance among Red, Green, and Blue color hues if images look garish or unrealistic.
RPC-6022GW Rackmount LCD Workstation 6.2.3 Language The Languages are shown in Table 6-5. Table 6-5: Language Menu This menu provides options for selecting ODS screen legends in a preferred language.
RPC-6022GW Rackmount LCD Workstation 6.2.4 OSD Configurations The OSD configurations are shown in Table 6-6. Table 6-6: OSD Configurations Menu OSD Configurations are described below. OSD Time Out: Determines how many seconds the OSD screen stays on screen before it disappears when OSD is left unattended. OSD Position: Adjusts the OSD position on the screen. Position 1 is in the upper left of the screen, position 2 in the upper right and position 3 in the center.
RPC-6022GW Rackmount LCD Workstation Aspect Ratio Adjusts the display ratio referring to the width of the screen and then to the height of the screen. 6.2.5 Signal The Signal menu in Table 6-7 enables manual selection of the type of graphic source input, i.e., analog (15-pin VGA) or digital (DVI-D).
RPC-6022GW Rackmount LCD Workstation 6.2.6 Backlight The Backlight menu in Table 6-8 enables users to configure the LCD backlight. Table 6-8: Backlight Menu Backlight Menu options are described below. Light Enabled: Turns backlight on or off. Light Contrast: Adjusts the backlight contrast. Light Brightness: Adjusts the backlight brightness. Light H Start: Adjusts the backlight projection area in the horizontal direction. Light H Width: Adjusts the width of the backlight projection area.
RPC-6022GW Rackmount LCD Workstation Chapter 7 7 Software Driver Page 87
RPC-6022GW Rackmount LCD Workstation NOTE: The following information is provided for workstations with touch screens. 7.1 Touch Screen Driver The touch screen controller enables analog resistive touch screens for four-wire, five-wire & eight-wire models. The controller directly communicates with the PC system through the touch screen communications interface. The controller design is superior in sensitivity, accuracy, and friendly operation.
RPC-6022GW Rackmount LCD Workstation 7.2 Driver Installation To install the touch screen software driver, please follow the steps below. Step 1: Insert the TouchKit driver CD that came with the RPC-6022GW rackmount workstation into the CD drive. Step 2: Once the CD drive is installed, the screen in Figure 7-1 appears. Table 7-1: Driver CD Pop Up Screen Step 3: Select the operating system installed on the system from the menu on the left side of the screen.
RPC-6022GW Rackmount LCD Workstation Step 4: Once the OS system is selected, the touch kit setup will prepare the install shield wizard (Table 7-2). Table 7-2: Install Shield Wizard Preparation Step 5: After the Install Shield Wizard is ready, a welcome screen appears (Table 7-3). Table 7-3: Welcome Screen Step 6: To continue the installation process click NEXT.
RPC-6022GW Rackmount LCD Workstation Step 7: An Install PS/2 interface driver screen appears (Table 7-4). It is not necessary to install the PS/2 interface driver. To continue click NEXT.
RPC-6022GW Rackmount LCD Workstation Step 8: Four point calibration options are then selected (Figure 7-5). Four point calibrations can be done every time a user boots up, during the next time the system boots or never. Select if and when a four-point calibration should be done. Click NEXT to continue.
RPC-6022GW Rackmount LCD Workstation Step 9: The user is then prompted to ensure the touch monitor or the USB for the touch controller is plugged into the system (Table 7-6). Once the touch controller is plugged into the system, click “OK.” Table 7-6: Touch Monitor/USB Touch Controller Confirmation Step 10: The user is then prompted to select multi-monitor system support (Figure 6-7). Make the appropriate selection and click NEXT to continue.
RPC-6022GW Rackmount LCD Workstation Step 11: The user is then prompted to select a file directory in which the touch kit controller is installed (Table 7-8). The default directory is “C:\Program Files\TouchKit.” If a different folder must be used, select browse and then select the folder. Once the folder is selected, click NEXT to continue.
RPC-6022GW Rackmount LCD Workstation Step 12: The user is then prompted to select a file directory in which the program icons are saved (Table 7-9). The default folder is “TouchKit.” If a different folder must be used, select a folder from the list shown. Once the folder is selected, click NEXT to continue.
RPC-6022GW Rackmount LCD Workstation Step 13: The program then starts installing (Table 7-10).
RPC-6022GW Rackmount LCD Workstation Step 14: Once the program is finished installing, the user is prompted to restart the computer now or to restart the computer later (Table 7-11). Select when the computer should be restarted and click “FINISH” to complete the driver installation procedure.Step 0: Table 7-11: Installation Complete 7.3 Touch Panel Driver Configuration To configure the touch screen driver options, refer to the TouchKit user manual located on the driver installation CD.
RPC-6022GW Rackmount LCD Workstation THIS PAGE IS INTENTIONALLY LEFT BLANK Page 98
RPC-6022GW Rackmount LCD Workstation Appendix A A Certification Page 99
RPC-6022GW Rackmount LCD Workstation A.1 RoHS Compliant All RPC-6022GW rackmount workstations comply with the Restriction of Hazardous Materials (RoHS) Directive. This means that all components used to build the industrial workstations and the workstation itself are RoHS compliant.
RPC-6022GW Rackmount LCD Workstation Appendix B B Recommended IEI Backplanes and PSUs Page 101
RPC-6022GW Rackmount LCD Workstation The following IEI backplanes and power supply options are recommended for the RPC-6022GW Rackmount LCD Workstation. For more information about these backplanes and power supply units, please contact an IEI sales representative or visit the IEI website (www.ieiworld.com). B.1 RPC-6022GW Backplane Options Table B-1 shows the backplane options for RPC-6022GW. PCIe Model No. SBC Type PCI PSU ISA x1 x4 x 16 Connector PCI-13SD-RS-R30 PICMG 1.
RPC-6022GW Rackmount LCD Workstation B.2 Power Supply Options Table B-2 shows the power supply options for RPC-6022GW. Type Model No.
RPC-6022GW Rackmount LCD Workstation THIS PAGE IS INTENTIONALLY LEFT BLANK Page 104
RPC-6022GW Rackmount LCD Workstation C Index Page 105
RPC-6022GW Rackmount LCD Workstation 3 F 3.5” to 5.25” drive adapter bracket ............46 fan bracket .................. 50, 53, 65, 72, 73, 74 A I Analog VGA ...............................................12 Install the Backplane..................................48 Install the CPU Card ..................................50 B Backplane Options...................................102 Backplane Replacement............................67 Install the PCI/ISA Expansion Card ...........
RPC-6022GW Rackmount LCD Workstation O Remove the Top Cover ..............................40 Replacing a 3.5” Disk Drive on a 5.25” Drive OSD Adapter Bracket.....................................75 Backlight................................................86 Color ......................................................82 S Language ..............................................83 Main Display Features...........................80 OSD Buttons .........................................