RPC-6010G Rackmount LCD Workstation Page i
RPC-6010G Rackmount LCD Workstation Revision MODEL RPC6010G Rackmount Workstation Revision Number Description Date of Issue 1.
RPC-6010G Rackmount LCD Workstation Copyright COPYRIGHT NOTICE The information in this document is subject to change without prior notice in order to improve reliability, design and function and does not represent a commitment on the part of the manufacturer. In no event will the manufacturer be liable for direct, indirect, special, incidental, or consequential damages arising out of the use or inability to use the product or documentation, even if advised of the possibility of such damages.
RPC-6010G Rackmount LCD Workstation Packing List NOTE: If any of the components listed in the checklist below are missing, please do not proceed with the installation. Contact the IEI reseller or vendor you purchased the RPC-6010G rackmount workstation from or contact an IEI sales representative directly. To contact an IEI sales representative, please send an email to sales@iei.com.tw. The items listed below should all be included in the RPC-6010G Rackmount Workstation package.
RPC-6010G Rackmount LCD Workstation Table of Contents 1 INTRODUCTION..................................................................................................... 1 1.1 RPC-6010G OVERVIEW............................................................................................. 2 1.2 RPC-6010G FEATURES .............................................................................................. 2 1.3 MODEL VARIATIONS ...............................................................................
RPC-6010G Rackmount LCD Workstation 4.2.3 Packing List ..................................................................................................... 20 4.3 PRE-INSTALLATION PREPARATION ............................................................................ 22 4.3.1 System Planning............................................................................................... 22 4.3.2 Tools ...........................................................................................................
RPC-6010G Rackmount LCD Workstation 5.7.1 3.5” Disk Drive Replacement .......................................................................... 57 5.7.2 5.25” Disk Drive Replacement ........................................................................ 58 6 ON SCREEN DISPLAY (OSD) CONTROLS ...................................................... 59 6.1 USER MODE OSD STRUCTURE ................................................................................ 60 6.1.1 OSD Buttons..............................
RPC-6010G Rackmount LCD Workstation List of Figures Figure 2-1: RPC-6010G Front Panel ............................................................................6 Figure 2-2: RPC-6010G Front Panel Door Open.........................................................7 Figure 2-3: RPC-6010G 14 Slot Rear Panel.................................................................8 Figure 2-4: RPC-6010G ATX Motherboard Rear Panel ..............................................9 Figure 2-5: RPC-6010G Right Side Panel...
RPC-6010G Rackmount LCD Workstation Figure 4-21: Install Workstation into Rack ...............................................................46 Figure 5-1: PSU External Retention Screws.............................................................52 Figure 5-2: PSU Internal Retention Screws ..............................................................52 Figure 5-3: PSU Mounting Bracket Retention Screws.............................................53 Figure 5-4: Cooling Fan Bracket External Screws...........
RPC-6010G Rackmount LCD Workstation List of Tables Table 1-1: RPC-6010G Model Variations .....................................................................3 Table 2-1: General Physical Dimensions ..................................................................10 Table 3-1: RPC-6010G Specifications .......................................................................14 Table 3-2: LCD Specifications....................................................................................
RPC-6010G Rackmount LCD Workstation Chapter 1 1 Introduction Page 1
RPC-6010G Rackmount LCD Workstation 1.1 RPC-6010G Overview The RPC-6010G is a PC/AT compatible computer designed for industrial applications. It has a rugged steel chassis specially designed to work under harsh environmental conditions while also being high reliability. The RPC-6010G supports 14-slot passive backplanes, ATX motherboards and a full line of dependable AC/DC power supplies. The RPC-6010G can withstand shock, vibration, dust and a wide range of temperatures in industrial environments.
RPC-6010G Rackmount LCD Workstation Touch Model Screen SBC Form Factor Expansion Slots ACE-R4140AP Redundant Power Supply RPC-6010GWR/ACE-R4140AP No Full-size CPU card 14 RPC-6010GWR/ACE-R4140AP/T-R Yes Full-size CPU card 14 RPC-6010GWATXR/ACE-R4140AP No ATX / microATX 7 RPC-6010GWATXR/ACE-R4140AP/T-R Yes ATX / microATX 7 Table 1-1: RPC-6010G Model Variations 1.
RPC-6010G Rackmount LCD Workstation THIS PAGE IS INTENTIONALLY LEFT BLANK Page 4
RPC-6010G Rackmount LCD Workstation Chapter 2 2 Mechanical Overview Page 5
RPC-6010G Rackmount LCD Workstation 2.1 External Overview The following sections describe the physical layout of the RPC-6010G rackmount workstation. 2.1.1 Front Panel The RPC-6010G rackmount workstation has the following front panel items: Plastic frame 8.4” Flat panel TFT LCD screen Lockable drive bay access door with 62 key membrane keypad and OSD controls conceals: o o o o o o Three 5.25” drive bays One 3.
RPC-6010G Rackmount LCD Workstation Figure 2-2: RPC-6010G Front Panel Door Open (Drives Not Included) 2.1.2 Rear Panel The RPC-6010G rackmount workstation is available with either a 14-slot rear panel bracket or an ATX motherboard rear panel bracket. The following sections list the 14-slot rear panel bracket and ATX motherboard rear panel bracket items. 2.1.2.
RPC-6010G Rackmount LCD Workstation Figure 2-3: RPC-6010G 14 Slot Rear Panel 2.1.2.2 ATX Motherboard Rear Panel The RPC-6010G rackmount workstation is available with two types of rear panel brackets.
RPC-6010G Rackmount LCD Workstation Figure 2-4: RPC-6010G ATX Motherboard Rear Panel 2.1.
RPC-6010G Rackmount LCD Workstation 2.1.4 Left Side Panel The RPC-6010G rackmount workstation has the following left side panel items: Cooling vents Figure 2-6: RPC-6010G Left Side Panel 2.2 Physical Dimensions The following sections describe the physical dimensions of the RPC-6010G. 2.2.1 General Physical Dimensions General physical dimensions for the RPC-6010G are shown in Table 2-1.
RPC-6010G Rackmount LCD Workstation 2.2.2 RPC-6010G Physical Dimensions The physical dimensions of the RPC-6010G are shown in Figure 2-1.
RPC-6010G Rackmount LCD Workstation THIS PAGE IS INTENTIONALLY LEFT BLANK Page 12
RPC-6010G Rackmount LCD Workstation Chapter 3 3 Detailed Specifications Page 13
RPC-6010G Rackmount LCD Workstation 3.1 RPC-6010G Specifications Table 3-1 shows the RPC-6010G specifications. LCD Type 8.4" TFT Input Interface VGA Max.
RPC-6010G Rackmount LCD Workstation 3.2 LCD Specifications Table 3-2 lists the RPC-6010G LCD specifications. Size 8.4” MFR/Model AUO/G084SN03 Resolution SVGA (800 x 600) Active Area (mm) 170.4 x 127.8 Pixel Pitch (mm) 0.213 Number of Colors 262K View Angle (H/V) 130 / 110 Brightness (cd/m2) 220 Contrast Ratio 500:1 Response Time (ms) (at 25C) 35 Power Consumption (W) 3.3 Interface 1ch LVDS Supply Voltage (V) 3.
RPC-6010G Rackmount LCD Workstation 3.3 ACE-832AP PSU Specifications Table 3-3 lists the ACE-832AP power supply specifications. INPUT Voltage 90 ~ 264VAC Full Range Frequency 50 ~ 60Hz Input Current 6A(RMS)@115VAC 3A(RMS)@230VAC Inrush Current 60A Max for 115VAC 90A Max for 230VAC OUTPUT Voltage Min. load Max. load Ripple & Noise +3.3V 0.3A 28A 50mV +5V 0.1A 30A 50mV +12V 0A 15A 120mV -5V 0A 0.3A 100mV -12V 0A 0.8A 120mV +5Vsb 0A 2A 100mV Total Current of +3.
RPC-6010G Rackmount LCD Workstation Chapter 4 4 Installation Page 17
RPC-6010G Rackmount LCD Workstation 4.1 Installation Considerations 4.1.1 Installation Precautions When installing the RPC-6010G, please follow the precautions listed below: Read the user manual: The user manual provides a complete description of the RPC-6010G rackmount workstation, installation instructions and configuration options. Turn Off Power: When installing the RPC-6010G rackmount workstation, make sure the power is off.
RPC-6010G Rackmount LCD Workstation Backplane/Motherboard: The backplane or motherboard installed in the RPC-6010G rackmount workstation is separately purchased. Disk Drives: Disk drives installed into the RPC-6010G rackmount workstation are separately purchased. Disk drive support is CPU card dependent. Before purchasing a CPU card or disk drives, please check the CPU card disk drive support. 4.2 Unpacking 4.2.1 Packaging When shipped, the RPC-6010G rackmount workstation is wrapped in a plastic bag.
RPC-6010G Rackmount LCD Workstation Step 3: Use box cutters, a knife or a sharp pair of scissors to open the top of the internal (first) box. Step 4: Lift the workstation out of the boxes. Step 5: Remove both polystyrene ends from each side. Step 6: Pull the plastic cover off the workstation. Step 7: Make sure all the components listed in the packing list are present. Step 0: 4.2.
RPC-6010G Rackmount LCD Workstation Quantity Description 2 Handle bracket 1 Mini-DIN 6 PS/2 connector cable 1 Power cable 1 Screw kit 7 Short card clamp 1 VGA cable 2 4-pin USB wire cable Image For Touch Panel (T-R) Models only 1 RS-232 cable 1 TouchKit Driver CD 1 Touch pen Table 4-1: Packing List Page 21
RPC-6010G Rackmount LCD Workstation 4.3 Pre-installation Preparation 4.3.1 System Planning User supplied CPU cards and backplanes or motherboards need to be installed in the system before installing the RPC-6010G rackmount workstation.
RPC-6010G Rackmount LCD Workstation 4.4 Installation Procedures 4.4.1 Preinstalled Components The following components are preinstalled in the RPC-6010G rackmount workstation. Power supply unit (PSU) Cooling fan module Drive bracket LCD screen 4.4.2 User Installed Components The following user supplied components need to be installed into the RPC-6010G rackmount workstation: Disk drives Backplane and CPU card, or motherboard PCI or ISA expansion cards (optional) 4.4.
RPC-6010G Rackmount LCD Workstation Step 10: Connect all required cables. Step 11: Reinstall the dual CPU card clamp and drive bay stabilizer bracket. Step 12: Reinstall the CPU card clamp. Step 13: Close the top cover. Step 14: Mount the workstation.Step 0: 4.5 Installing Components into the RPC-6010G NOTE: This section gives a generic description of the component installation process for the RPC-6010G rackmount workstation.
RPC-6010G Rackmount LCD Workstation 4.5.1 Remove the Top Cover The top cover is secured to the RPC-6010G rackmount workstation with six screws (three each on the left and right panels). To remove the top cover, please follow the steps below. Step 1: Remove the six top cover retention screws (three each on the left and right panels). (See Figure 4-1) Figure 4-1: Top Cover Left Side Retention Screws (Right Side Similar) Step 2: Remove the top cover from the chassis to reveal the internal components.
RPC-6010G Rackmount LCD Workstation 4.5.2 Remove the CPU Card Clamp The CPU card clamp is secured to the RPC-6010G rackmount workstation with four retention screws. To remove the CPU card clamp, please follow the steps below. Step 1: Remove four retention screws, two each on the left and right sides of the workstation, that secure the CPU card clamp to the chassis (Figure 4-3). Figure 4-3: CPU Card Clamp Right Side Retention Screws (Left Side Similar) Step 2: Remove the CPU card clamp from the chassis.
RPC-6010G Rackmount LCD Workstation Figure 4-4: Dual CPU Card Clamp and Drive Bay Stabilizer Bracket Right Side Retention Screws (Left Side Similar) Step 2: Remove the four retention screws that secure the dual CPU card clamp and drive bay stabilizer bracket to the fan bracket ( Figure 4-5).
RPC-6010G Rackmount LCD Workstation Step 3: Remove the CPU card clamp and drive bay bracket from the chassis.Step 0: 4.5.4 Remove the Drive Bracket The drive bracket is secured to the RPC-6010G rackmount workstation with four retention screws. To remove the drive bracket, please follow the steps below. Step 1: Remove four retention screws that secure the drive bracket to the chassis (Figure 4-4). Figure 4-6: Drive Bracket Retention Screws Step 2: Remove the drive bracket from the chassis.Step 0: 4.5.
RPC-6010G Rackmount LCD Workstation Figure 4-7: Drive Slot Blank Plate Retention Screws (Other Side Similar) Step 2: Remove the drive slot blank plate from the drive bracket.Step 0: 4.5.6 Install Drives 4.5.6.1 5.25” Disk Drive The drive bracket supports three 5.25” disk drives. To install a 5.25” disk drive, follow the instructions below. Step 1: Remove the dual CPU card clamp and drive bay stabilizer bracket from the RPC-6010G rackmount workstation (see Section 4.5.3).
RPC-6010G Rackmount LCD Workstation Step 5: Insert the appropriate number of retention screws into each side of the 5.25” disk drive through the drive bracket (Figure 4-8).Step 0: Figure 4-8: 5.25” Disk Drive Retention Screws (Other Side Similar) 4.5.6.2 3.5” Disk Drive in a 5.25” Slot With the use of IEI’s 3.5” to 5.25” drive bay rack, a standard 3.5” disk drive can be installed into a 5.25” drive bay slot. To install a 3.5” hard disk drive into a 5.
RPC-6010G Rackmount LCD Workstation Figure 4-9: 3.5” to 5.25” Drive Bay Rack Retention Screws (Other Side Similar) Step 3: Remove the dual CPU card clamp and drive bay stabilizer bracket from the RPC-6010G rackmount workstation (see Section 4.5.3). Step 4: Remove the drive bracket from the RPC-6010G rackmount workstation (see Section 4.5.4). Step 5: Remove the appropriate drive slot blank plate (see Section 4.5.5). Step 6: Install the 3.5” to 5.25” drive bay rack into the drive bracket (see Section 4.5.6.
RPC-6010G Rackmount LCD Workstation Step 4: Slide a 3.5” disk drive into one of the 3.5” drive brackets. Make sure the connectors of the drive are facing the rear of the drive bracket. Step 5: Insert the appropriate number of retention screws into each side of the 3.5” disk drive through the 3.5” drive bracket (Figure 4-10).Step 0: Figure 4-10: 3.5” Disk Drive Retention Screws 4.5.7 Reinstall the Drive Bracket After the drives have been installed, reinstall the drive bracket into the chassis.
RPC-6010G Rackmount LCD Workstation 4.5.8 Install the Backplane To install a backplane, follow the instructions below. Step 1: Install the correct amount of copper pillars and plastic spacers into the base of the chassis (Figure 4-11). NOTE: The backplane shown in Figure 4-11 is an example for reference only. The location and number of copper pillars and plastic spacers depends on the backplane being used.
RPC-6010G Rackmount LCD Workstation Step 2: Mount the backplane into the chassis. Make sure the backplane is positioned so that when the CPU card and PCI/ISA expansion cards are installed, both the CPU card and the PCI/ISA card I/O connectors face the I/O brackets on the rear panel. Step 3: Align the retention screw holes in the backplane with the copper pillars installed in Step 1.
RPC-6010G Rackmount LCD Workstation 4.5.9 Install the CPU Card CAUTION Before a CPU card is inserted into the backplane, make sure the CPU card has been correctly prepared and that all the CPU card jumper settings are configured correctly. For CPU card component installation procedures, please refer to the user manual that came with the CPU card.
RPC-6010G Rackmount LCD Workstation Figure 4-13: Slot Cover Retention Screw Step 2: Remove the CPU card clamp. (See Section 4.5.2) Step 3: Remove the dual CPU card clamp and drive bay stabilizer bracket. (See Section 4.5.3) Step 4: Slide the CPU card into the reserved PCI/ISA socket on the backplane. Make sure the back edge of the CPU card slides into the plastic guide rails at the front end of the chassis.
RPC-6010G Rackmount LCD Workstation Figure 4-14: Install the CPU Card Step 5: To secure the CPU card, reinsert the previously removed slot cover retention screw. Step 6: If a PCI/ISA expansion card is not being installed, reinstall the dual CPU card clamp and drive bay stabilizer bracket and the CPU card clamp. If a PCI/ISA expansion card is being installed, proceed to the next section.Step 0: 4.5.
RPC-6010G Rackmount LCD Workstation Step 2: If necessary, remove the CPU card clamp. (See Section 4.5.2) Step 3: If necessary, remove the dual CPU card clamp and drive bay stabilizer bracket. (See Section 4.5.3) Step 4: Slide the PCI/ISA expansion card into the reserved PCI/ISA socket on the backplane. Step 5: To secure the PCI/ISA expansion card, reinsert the previously removed slot cover retention screw. Step 0: Step 1: If necessary, reinstall the CPU card clamp.
RPC-6010G Rackmount LCD Workstation Figure 4-15: Installing a Short Card 4.5.12 Connect the Cables The following cables may have to be connected depending on the CPU card and the backplane installed in the system: PSU cables must be connected to the following components (if installed): o o o o o CPU card Backplane FDD HDD Optical drive Disk drive ribbon cables must be connected to the corresponding CPU card disk drive connectors.
RPC-6010G Rackmount LCD Workstation 4.5.
RPC-6010G Rackmount LCD Workstation NOTE: This section gives a generic description of the rack mounting process for the RPC-6010G rackmount workstation. Alternate rack mounting systems may require different mounting procedures. Be sure to follow the manufacturer’s instructions when mounting the workstation. To rack mount the workstation, please follow the steps below. Step 1: The left and right side panels of the workstation each have four screw holes for rack handle bracket installation.
RPC-6010G Rackmount LCD Workstation Step 2: Remove the rack slides from the rack slide brackets. (See Figure 4-17) Figure 4-17: Remove Rack Slide Step 3: The left and right side panels of the workstation each have five screw holes for rack slides. Attach one slide section each to the left and right side panel of the workstation.
RPC-6010G Rackmount LCD Workstation Figure 4-18: Workstation Slide Installation (Other Side Similar) Step 4: Assemble the slide brackets per the manufacturer’s instructions.
RPC-6010G Rackmount LCD Workstation Figure 4-19: Rack Slide Bracket Assembly Step 5: Attach the slide brackets to the rack per the manufacturer’s instructions.
RPC-6010G Rackmount LCD Workstation Figure 4-20: Rack Slide Bracket Installation Step 6: Insert the workstation with the attached slides into the rack slide brackets until the handle brackets are flush against the rack.
RPC-6010G Rackmount LCD Workstation Figure 4-21: Install Workstation into Rack Step 7: If necessary, secure the workstation handle brackets to the rack with the fasteners that came with the workstation.
RPC-6010G Rackmount LCD Workstation Chapter 5 5 Maintenance Page 47
RPC-6010G Rackmount LCD Workstation 5.1 Maintenance Overview Maintaining the RPC-6010G rackmount workstation is essential for the smooth operating of system applications. Maintaining the system might mean replacing failed components during the lifetime of the workstation. The following RPC-6010G components can be replaced. CPU card PCI/ISA expansion card Backplane Power supply unit (PSU) Cooling fans Disk drives o o 3.5” 5.
RPC-6010G Rackmount LCD Workstation Step 3: Open the top cover of the RPC-6010G rackmount workstation. (See Section 4.5.1) Step 4: Disconnect all internal and external peripheral device connections from the CPU card. Step 5: Remove the CPU card clamp. (See Section 4.5.2) Step 6: Remove the dual CPU card clamp and drive bay stabilizer bracket. (See Section 4.5.3) Step 7: Remove the retention screw that secures the CPU card to the slot on the rear panel. Step 8: Slide the CPU card out of the workstation.
RPC-6010G Rackmount LCD Workstation Step 5: Remove the CPU card clamp. (See Section 4.5.2) Step 6: Remove the dual CPU card clamp and drive bay stabilizer bracket. (See Section 4.5.3) Step 7: Remove the retention screw that secures the PCI/ISA expansion card to the slot on the rear panel. Step 8: Slide the PCI/ISA expansion card out of the workstation. Step 9: Install a new PCI/ISA expansion card. (See Section 4.5.10) Step 10: Reinstall the CPU card clamp.
RPC-6010G Rackmount LCD Workstation Step 7: Remove the retention screws that secure the backplane to the workstation (see Section 4.5.8). Step 8: Install a new backplane into the chassis. Step 9: Reinstall and reconnect all CPU cards (see Section 4.5.9) and PCI/ISA expansion cards (see Section 4.5.10). Step 10: Reinstall the CPU card clamp. Step 11: Reinstall the dual CPU card clamp and drive bay stabilizer bracket. Step 12: Reinstall the top cover of the workstation.
RPC-6010G Rackmount LCD Workstation Figure 5-1: PSU External Retention Screws Step 7: Remove the two internal retention screws that secure the PSU assembly to the right side panel of the workstation (Figure 5-2).
RPC-6010G Rackmount LCD Workstation Step 8: Remove the two retention screws on the PSU mounting bracket (Figure 5-3). Figure 5-3: PSU Mounting Bracket Retention Screws Step 9: Reattach the PSU mounting bracket to the new PSU with the two previously removed retention screws. Step 10: Install the new PSU into the workstation making sure the PSU power connector and PSU cooling fan are facing out of the workstation.
RPC-6010G Rackmount LCD Workstation 5.6 Cooling Fan Replacement To replace a cooling fan, please follow the instructions below. CAUTION: Carefully note the direction and orientation of the existing cooling fan prior to replacement. Step 1: Turn off and disconnect the workstation from all power sources. Step 2: Remove the workstation from the rack in which it is installed. Step 3: Open the top cover of the RPC-6010G rackmount workstation. (See Section 4.5.1) Step 4: Remove the CPU card clamp.
RPC-6010G Rackmount LCD Workstation Figure 5-4: Cooling Fan Bracket External Screws Step 9: Remove the three retention screws that secure the cooling fan bracket to the bottom of the workstation.
RPC-6010G Rackmount LCD Workstation Step 10: Remove the fan from the bracket by removing the four retention screws. (See Figure 5-6) Figure 5-6: Fan Retention Screws Step 11: Place the new fan into the bracket. Align the retention screw holes in the new fan with those in the bracket and reinsert the four retention screws. Step 12: Connect the new cooling fan to the PSU. Step 13: Reinstall the three retention screws that secure the cooling fan bracket to the bottom of the workstation.
RPC-6010G Rackmount LCD Workstation Step 18: Reinstall the top cover of the workstation. Step 19: Reinstall the workstation into the rack. Refer to Section 4.6 for complete mounting instructions.Step 0: 5.7 Disk Drive Replacement 5.7.1 3.5” Disk Drive Replacement To replace a 3.5” disk drive, please follow the instructions below. Step 1: Turn off and disconnect the workstation from all power sources. Step 2: Remove the workstation from the rack in which it is installed.
RPC-6010G Rackmount LCD Workstation 5.7.2 5.25” Disk Drive Replacement To replace a 5.25” disk drive, please follow the instructions below. NOTE: These instructions are also applicable for replacement of a 3.5” disk drive mounted in a 5.25” disk drive adapter bracket. Refer to Section 4.5.6.2 for instructions on installing a 3.5” disk drive into a 5.25” drive bay slot. Step 1: Turn off and disconnect the workstation from all power sources.
RPC-6010G Rackmount LCD Workstation Chapter 6 6 On Screen Display (OSD) Controls Page 59
RPC-6010G Rackmount LCD Workstation 6.1 User Mode OSD Structure 6.1.1 OSD Buttons There are several on-screen-display (OSD) control buttons on the front panel of the workstation. Figure 6-1 shows a typical arrangement of OSD controls. Figure 6-1: OSD Control Buttons NOTE: Pressing the direction keys (LEFT or RIGHT) can bring out a simple menu that adjusts the LCD screen brightness and contrast values.
RPC-6010G Rackmount LCD Workstation 6.1.2 OSD Menu Structure Table 6-1 shows the OSD menu structure. Level 0 Level 1 Value Main Display Features Menu Brightness 0 to 100 Contrast 0 to 100 Horizontal Size 0 to 100 Phase 0 to 100 H. Position 0 to 100 V. Position 0 to 100 Sharpness 1 to 5 Volume This menu is currently disabled, Mute and will be implemented with Speaker models equipped with speakers.
RPC-6010G Rackmount LCD Workstation Level 0 Level 1 Value Signal Menu Digital Select Analog Backlight Menu Light Enable On or Off Light Contrast 0 to 100 Light Brightness 0 to 100 Light H Start 0 to 100 Light H Width 0 to 100 Light V Start 0 to 100 Light V Height 0 to 100 Table 6-1: OSD Menus 6.2 Using the OSD OSD menu options are described below. 6.2.1 Main Display Features Main display features are shown in Figure 6-2.
RPC-6010G Rackmount LCD Workstation Brightness: The brightness option adjusts the brightness of screen. This function adjusts the offset value of ADC. Setting this value too high or too low will affect the quality of image. Contrast: This function adjusts the gain value of ADC. Adjusting this value too high or too low will worsen the quality of image. Horizontal Size: This item adjusts the screen size in the horizontal direction.
RPC-6010G Rackmount LCD Workstation 6.2.2 Color Color options are shown in Figure 6-3. Figure 6-3: Color Options The Color menu fine-tunes the palette of color hues for the LCD. 9300: NTSC standard Kelvin 7500: NTSC standard Kelvin 6500: NTSC standard Kelvin User: This item allows fine-tuning the balance among Red, Green, and Blue color hues if images look garish or unrealistic.
RPC-6010G Rackmount LCD Workstation 6.2.3 Language The Languages are shown in Figure 6-4. Figure 6-4: Language Menu This menu provides options for selecting ODS screen legends in a preferred language.
RPC-6010G Rackmount LCD Workstation 6.2.4 OSD Configurations The OSD configurations are shown in Figure 6-5. Figure 6-5: OSD Configurations Menu OSD Configurations are described below. OSD Time Out: Determines how many seconds the OSD screen stays on screen before it disappears when OSD is left unattended. OSD Position: Adjusts the OSD position on the screen. Position 1 is in the upper left of the screen, position 2 in the upper right and position 3 in the center.
RPC-6010G Rackmount LCD Workstation Aspect Ratio Adjusts the display ratio referring to the width of the screen and then to the height of the screen. 6.2.5 Signal The Signal menu in Figure 6-6 enables manual selection of the type of graphic source input, i.e., analog (15-pin VGA) or digital (DVI-D).
RPC-6010G Rackmount LCD Workstation 6.2.6 Backlight The Backlight menu in Figure 6-7 enables users to configure the LCD backlight. Figure 6-7: Backlight Menu Backlight Menu options are described below. Light Enabled: Turns backlight on or off. Light Contrast: Adjusts the backlight contrast. Light Brightness: Adjusts the backlight brightness. Light H Start: Adjusts the backlight projection area in the horizontal direction. Light H Width: Adjusts the width of the backlight projection area.
RPC-6010G Rackmount LCD Workstation Chapter 7 7 Software Driver Page 69
RPC-6010G Rackmount LCD Workstation NOTE: The following information is provided for workstations with touch screens. 7.1 Touch Screen Driver The touch screen controller enables analog resistive touch screens for four-wire, five-wire & eight-wire models. The controller directly communicates with the PC system through the touch screen communications interface. The controller design is superior in sensitivity, accuracy, and friendly operation.
RPC-6010G Rackmount LCD Workstation 7.2 Driver Installation To install the touch screen software driver, please follow the steps below. Step 1: Insert the TouchKit driver CD that came with the RPC-6010G rackmount workstation into the CD drive. Step 2: Once the CD drive is installed, the screen in Figure 7-1 appears. Figure 7-1: Driver CD Pop Up Screen Step 3: Select the operating system installed on the system from the menu on the left side of the screen.
RPC-6010G Rackmount LCD Workstation Step 4: Once the OS system is selected, the touch kit setup will prepare the install shield wizard (Figure 7-2). Figure 7-2: Install Shield Wizard Preparation Step 5: After the Install Shield Wizard is ready, a welcome screen appears (Figure 7-3). Figure 7-3: Welcome Screen Step 6: To continue the installation process click NEXT.
RPC-6010G Rackmount LCD Workstation Step 7: An Install PS/2 interface driver screen appears (Figure 7-4). It is not necessary to install the PS/2 interface driver. To continue click NEXT. Figure 7-4: Install PS/2 Interface Driver Step 8: Four point calibration options are then selected (Figure 7-5). Four point calibrations can be done every time a user boots up, during the next time the system boots or never. Select if and when a four-point calibration should be done. Click NEXT to continue.
RPC-6010G Rackmount LCD Workstation Figure 7-5: Install PS/2 Interface Driver Step 9: The user is then prompted to ensure the touch monitor or the USB for the touch controller is plugged into the system (Figure 7-6). Once the touch controller is plugged into the system, click “OK.
RPC-6010G Rackmount LCD Workstation Step 10: The user is then prompted to select multi-monitor system support (Figure 6-7). Make the appropriate selection and click NEXT to continue.
RPC-6010G Rackmount LCD Workstation Step 11: The user is then prompted to select a file directory in which the touch kit controller is installed (Figure 7-8). The default directory is “C:\Program Files\TouchKit.” If a different folder must be used, select browse and then select the folder. Once the folder is selected, click NEXT to continue.
RPC-6010G Rackmount LCD Workstation Step 12: The user is then prompted to select a file directory in which the program icons are saved (Figure 7-9). The default folder is “TouchKit.” If a different folder must be used, select a folder from the list shown. Once the folder is selected, click NEXT to continue.
RPC-6010G Rackmount LCD Workstation Step 13: The program then starts installing (Figure 7-10).
RPC-6010G Rackmount LCD Workstation Step 14: Once the program is finished installing, the user is prompted to restart the computer now or to restart the computer later (Figure 7-11). Select when the computer should be restarted and click “FINISH” to complete the driver installation procedure.Step 0: Figure 7-11: Installation Complete 7.3 Touch Screen Driver Configuration To configure the touch screen driver options, refer to the TouchKit user manual located on the driver installation CD.
RPC-6010G Rackmount LCD Workstation THIS PAGE IS INTENTIONALLY LEFT BLANK Page 80
RPC-6010G Rackmount LCD Workstation Appendix A A Certifications Page 81
RPC-6010G Rackmount LCD Workstation A.1 RoHS Compliant All RPC-6010G rackmount workstations comply with the Restriction of Hazardous Materials (RoHS) Directive. This means that all components used to build the industrial workstations and the workstation itself are RoHS compliant.
RPC-6010G Rackmount LCD Workstation Appendix B B Recommended IEI Backplanes, Motherboards and PSUs Page 83
RPC-6010G Rackmount LCD Workstation The following IEI backplanes, motherboards and power supply units are recommended for the RPC-6010G rackmount workstation. For more information about these backplanes please contact an IEI sales representative or visit the IEI website (www.ieiworld.com). B.1 Recommended IEI Backplanes and Motherboards The following table lists the recommended IEI backplanes and motherboards for the RPC-6010G rackmount workstation.
RPC-6010G Rackmount LCD Workstation B.2 Recommended IEI Power Supply Units The following table lists the recommended IEI power supply units for the RPC-6010G rackmount workstation. Type Model No.
RPC-6010G Rackmount LCD Workstation THIS PAGE IS INTENTIONALLY LEFT BLANK Page 86
RPC-6010G Rackmount LCD Workstation C Index Page 87
RPC-6010G Rackmount LCD Workstation Installation Steps ...................................23 A ACE-832AP PSU Specifications................16 Active Area.................................................15 B PCI/ISA Expansion Card .......................37 Precautions............................................18 Preinstalled Components ......................23 Prerequisites..........................................18 Remove the CPU Card Clamp ..............26 Remove the Drive Bracket ...................
RPC-6010G Rackmount LCD Workstation N S Number of Colors.......................................15 Shock .........................................................14 Specifications .............................................14 O On Screen Display (OSD) .........................59 T Touch Screen Driver ..................................70 P Packing List .......................................... iv, 20 Pixel Pitch ..................................................15 Touch Screen Driver Configuration..