Instruction Manual

PPC-5152-D525 Falt-bezel Panel PC
Page 79
Î Serial Port 4 Mode [RS422/485]
The Serial Port 4 Mode option shows the Serial Port 4 signaling mode is set to
RS-422/485 and can not be changed.
5.3.5.1.5 Serial Port 5 Configuration
Î Serial Port [Enabled]
Use the Serial Port option to enable or disable the serial port.
Î
Disabled
Disable the serial port
Î
Enabled DEFAULT
Enable the serial port
Î Change Settings [Auto]
Use the Change Settings option to change the serial port IO port address and interrupt
address.
Î
Auto DEFAULT
The serial port IO port address and interrupt address
are automatically detected.
Î
IO=2E0h;
IRQ=7
Serial Port I/O port address is 2E0h and the interrupt
address is IRQ7
Î
IO=3F8h;
IRQ=3, 4,
5, 6, 7, 10,
11, 12
Serial Port I/O port address is 3F8h and the interrupt
address is IRQ3, 4, 5, 6, 7, 10, 11, 12
Î
IO=2F8h;
IRQ=3, 4,
5, 6, 7, 10,
11, 12
Serial Port I/O port address is 2F8h and the interrupt
address is IRQ3, 4, 5, 6, 7, 10, 11, 12