Owner's manual

ECN-360A-D2550 Embedded System
Page 63
o VSB3V
o VBAT
5.3.7.1 Smart Fan Mode Configuration
Use the Smart Fan Mode Configuration submenu (BIOS Menu 11) to configure fan
temperature and speed settings.
Aptio Setup Utility Copyright (C) 2011 American Megatrends, Inc.
Advanced
Smart Fan Mode Configuration
CPU_FAN1 Smart Fan Control [Auto Duty-Cycle Mode]
CPU Temperature 1 60
CPU Temperature 2 50
CPU Temperature 3 40
CPU Temperature 4 30
SYS_FAN1 Smart Fan Control [Auto Duty-Cycle Mode]
System Temperature 1 60
System Temperature 2 50
System Temperature 3 40
System Temperature 4 30
Smart Fan Mode Select
---------------------

: Select Screen
: Select Item
Enter: Select
+/-: Change Opt.
F1: General Help
F2: Previous Values
F3: Optimized Defaults
F4: Save & Exit
ESC: Exit
Version 2.14.1219. Copyright (C) 2011 American Megatrends, Inc.
BIOS Menu 11: Smart Fan Mode Configuration
CPU_FAN1/SYS_FAN1 Smart Fan Control [Auto Duty-Cycle Mode]
Use the CPU_FAN1 or SYS_FAN1 Smart Fan Control option to configure the CPU or
System Smart Fan.
Auto
Duty-Cycle
Mode
DEFAULT
The fan adjusts its speed using Auto Duty-Cycle
settings
Manual Duty
Mode
The fan spins at the speed set in Manual Duty
Mode settings
CPU/Sys tem Temperature n
Use the + or key to change the fan CPU or System Temperature n value. Enter a
decimal number between 1 and 100.