AUPS-C20 UPS Module IEI Technology Corp. MODEL: AUPS-C20 VESA Mount Intelligent UPS Module, 9 V ~ 28 V DC Input, 100 W Power Output, Network Remote Management Support User Manual Page i Rev. 1.
AUPS-C20 UPS Module Revision Date Version Changes 30 October, 2012 1.01 Updated the DC input range to 9 V ~ 28 V 14 June, 2012 1.
AUPS-C20 UPS Module Copyright COPYRIGHT NOTICE The information in this document is subject to change without prior notice in order to improve reliability, design and function and does not represent a commitment on the part of the manufacturer. In no event will the manufacturer be liable for direct, indirect, special, incidental, or consequential damages arising out of the use or inability to use the product or documentation, even if advised of the possibility of such damages.
AUPS-C20 UPS Module Table of Contents 1 INTRODUCTION.......................................................................................................... 1 1.1 INTRODUCTION........................................................................................................... 2 1.2 FEATURES ................................................................................................................... 2 1.3 EXTERNAL OVERVIEW .......................................................................
AUPS-C20 UPS Module 4.2.3.3 Battery Detection ...................................................................................... 30 4.2.4 Battery Information.......................................................................................... 31 4.2.5 LAN Setting ...................................................................................................... 32 4.2.6 Setting .............................................................................................................. 33 4.
AUPS-C20 UPS Module List of Figures Figure 1-1: AUPS-C20 ....................................................................................................................2 Figure 1-2: AUPS-C20 I/O Interface Connectors .........................................................................3 Figure 1-3: AUPS-C20 LED Indicators ..........................................................................................4 Figure 1-4: AUPS-C20 Dimensions (mm) ..................................................
AUPS-C20 UPS Module Figure 4-18: Battery Detection ....................................................................................................30 Figure 4-19: Battery Information .................................................................................................31 Figure 4-20: LAN Setting..............................................................................................................32 Figure 4-21: Application Setting .......................................................
AUPS-C20 UPS Module List of Tables Table 1-1: LED Indications.............................................................................................................4 Table 1-2: Total Battery Capacity Indications..............................................................................5 Table 1-3: AUPS-C20 Specifications.............................................................................................7 Table 1-4: AUPS-C20 Battery Specifications ..........................................
AUPS-C20 UPS Module Chapter 1 1 Introduction Page 1
AUPS-C20 UPS Module 1.1 Introduction Figure 1-1: AUPS-C20 The highly efficient, high-performance AUPS-C20 UPS (Uninterruptible Power Supply) module could be installed with four Li-ion batteries to provide stable 12V output and uninterruptible power to the IEI AFOLUX series panel PCs. The UPS module also receives a wide range of inputs between 9 V and 28 V DC. The AUPS-C20 is built on an intelligent design and provides outstanding line and load regulations.
AUPS-C20 UPS Module Supports PC-based utility for monitoring power and battery status Auto shut down when battery low Provides stable power to AFOLUX PPC during line sags and spikes Absorb power surges and transients 1.3 External Overview 1.3.
AUPS-C20 UPS Module 1.3.2 LED Indicators The side panel of the AUPS-C20 has six LED indicators to indicate the power and battery status (Figure 1-3). Figure 1-3: AUPS-C20 LED Indicators All the LED statuses are listed in Table 1-1.
AUPS-C20 UPS Module To see the approximate total battery capacity, press the DC output on/off button for four seconds. The LED indicators will light up, showing the corresponding total battery capacity as listed in Table 1-2.
AUPS-C20 UPS Module 1.4 Dimensions The main dimensions of the AUPS-C20 are shown in the diagram below.
AUPS-C20 UPS Module 1.5 Technical Specifications The AUPS-C20 technical specifications are listed below. Specification/Model AUPS-C20 VESA Type VESA 75 and VESA 100 Input Output Protection Regulatory Input voltage DC +9V ~ +28V Standby power consumption 0.3A (0.2A if Network Management is disabled) Charging time 8~12 hrs Output voltage DC +12 V +/-5% Output current Max. 7.
AUPS-C20 UPS Module 1.6 Battery Specifications The AUPS-C20 can be installed with four Li-ion smart batteries. The Li-ion battery specifications are listed below. Specification/Battery Model BAT-LI-4S2P3800 Battery Type Li-ion Nominal Capacity 3800 mAH Nominal Voltage 14.8 V Max. Charge Voltage 16.8 V Cut Off Voltage 11.2 V Recommended Charge Current (Max.) 2A System Continuous Discharging Current (Max.) 7.
AUPS-C20 UPS Module Chapter 2 2 Packing List Page 9
AUPS-C20 UPS Module 2.1 Anti-static Precautions WARNING! Static electricity can destroy certain electronics. Make sure to follow the ESD precautions to prevent damage to the product, and injury to the user. Make sure to adhere to the following guidelines: Wear an anti-static wristband: Wearing an anti-static wristband can prevent electrostatic discharge. Self-grounding: Touch a grounded conductor every few minutes to discharge any excess static buildup.
AUPS-C20 UPS Module 2.3 Packing List NOTE: If any of the components listed in the checklist below are missing, do not proceed with the installation. Contact the IEI reseller or vendor the AUPS-C20 was purchased from or contact an IEI sales representative directly by sending an email to sales@iei.com.tw.
AUPS-C20 UPS Module Quantity Item 1 DC output switch cable 1 USB Type A to mini-B cable 1 Screw kit 2 Wall mount bracket 1 Utility software CD Table 2-1: Packing List Page 12 Image
AUPS-C20 UPS Module Chapter 3 3 Installation Page 13
AUPS-C20 UPS Module 3.1 Anti-static Precautions WARNING: Failure to take ESD precautions during the installation of the AUPS-C20 may result in permanent damage to the AUPS-C20 and severe injury to the user. Electrostatic discharge (ESD) can cause serious damage to electronic components, including the AUPS-C20. Dry climates are especially susceptible to ESD.
AUPS-C20 UPS Module 3.3 Installation and Configuration Steps The following installation steps must be followed. Step 1: Unpack the UPS module Step 2: Install the battery packs Step 3: Mount UPS module to the AFOLUX panel PC Step 4: Connect the UPS module to the AFOLUX panel PC 3.4 Installing the Battery Packs NOTE: Before installing the battery packs into the AUPS-C20, it is recommended to press the MCU reset button to return the AUPS-C20 to the factory default settings.
AUPS-C20 UPS Module Step 2: Remove the five battery board retention screws (Figure 3-2) and lift the battery board off the AUPS-C20 module. Figure 3-2: Battery Board Retention Screws Step 3: Remove the six battery bracket retention screws (Figure 3-3) and lift the battery bracket off the AUPS-C20 module.
AUPS-C20 UPS Module Step 4: Install battery 1 and battery 2 into the AUPS-C20 (Figure 3-4). Make sure the battery packs are connected to the battery connectors on the board (Figure 3-4). Figure 3-4: Battery Pack Installation Step 5: Secure each battery pack with two retention screws (Figure 3-4). Step 6: Replace the battery bracket and battery board (Figure 3-5).
AUPS-C20 UPS Module Step 7: Install battery 3 and battery 4 into the AUPS-C20 (Figure 3-6). Make sure the battery packs are connected to the battery connectors on the battery board (Figure 3-6). Figure 3-6: Battery Pack Installation On The Upper Layer Step 8: Secure each battery pack with two retention screws (Figure 3-6). Step 9: Replace the top cover. 3.5 Mounting the AUPS-C20 To mount the AUPS-C20 onto the rear panel of the AFOLUX panel PC, follow the steps below.
AUPS-C20 UPS Module Figure 3-7: Mounting Bracket Installation Step 2: Install the AUPS-C20 onto the rear panel of the AFOLUX panel PC. Place the AUPS-C20 onto the mounting bracket. Secure the AUPS-C20 to the bracket with five retention screws, one on the rear panel and two on each side panel (Figure 3-8).
AUPS-C20 UPS Module 3.6 Connecting the AUPS-C20 To support the UPS function to the panel PC, the AUPS-C20 must be connected to the power source and to the panel PC. Figure 3-9 shows the connections.
AUPS-C20 UPS Module Chapter 4 4 Software Application Page 21
AUPS-C20 UPS Module 4.1 Introduction The IEI AUPS Battery Status Monitor application detects the information of the smart battery and monitors the battery status. 4.2 Monitoring DC Power and Smart Battery 4.2.1 Driver Installation Follow the steps below to install the necessary drivers. Step 1: Insert the driver CD into the system. Open the x:\Driver directory. Double click the CP210x_VCP_Win_XP_S2K3_Vista_7 icon. The InstallShield Wizard prepares the setup as shown (Figure 4-1).
AUPS-C20 UPS Module Step 2: A welcome screen appears (Figure 4-2). To continue the installation process click Next. Figure 4-2: Driver Welcome Screen Step 3: The license agreement in Figure 4-3 appears. Read the License Agreement. Check I accept the terms of license agreement and click Next to continue.
AUPS-C20 UPS Module Step 4: The Choose Destination Location window appears (Figure 4-4). Select a folder to install the driver. Figure 4-4: Choose Destination Location Step 5: Click Next and the InstallShield Wizard is ready to install the driver (Figure 4-5). Step 6: Click Install to start the installation.
AUPS-C20 UPS Module Step 7: The InstallShield Wizard Complete window appears (Figure 4-6). Check Launch the CP210x VCP Driver Installer and click Finish to launch the CP210x USB to UART Bridge Driver Installer. Figure 4-6: InstallShield Wizard Complete Screen Step 8: Click Install to start installing the CP210x USB to UART Bridge driver (Figure 4-7). Figure 4-7: CP210x USB to UART Bridge Driver Installer Step 9: When the installation is complete, the screen in Figure 4-8 appears. Click Finish to exit.
AUPS-C20 UPS Module 4.2.2 Application Installation Follow the steps below to install the AUPS Battery Status Monitor application. Step 1: Insert the driver CD into the system. Open the x:\AUPS_2.6_setup\ AUPS_SetupV2.6 directory. Double click the AUPS_Setup v2.6 icon. Step 2: A welcome screen appears (Figure 4-9). To continue the installation process, click Next.
AUPS-C20 UPS Module Step 3: The Select Installation Folder window appears (Figure 4-10). Select a folder to install the application. Figure 4-10: Select Installation Folder Step 4: Click Next and the Installshield Wizard is ready to install the program (Figure 4-11).
AUPS-C20 UPS Module Step 5: Click Next to continue. The Installing AUPS_Setup screen appears as the program is installed (Figure 4-12). Figure 4-12: Installing AUPS Step 6: The Installation Complete window appears (Figure 4-13). Click Close to exit.
AUPS-C20 UPS Module Step 7: To launch the application, double click the shortcut (Figure 4-14) on the desktop. Figure 4-14: AUPS Battery Status Monitor Application 4.2.3 Status Information The IEI AUPS Battery Status Monitor application shows the DC power status and battery status (Figure 4-15). The following sections describe the status information in details. Figure 4-15: Status Information 4.2.3.
AUPS-C20 UPS Module 4.2.3.2 Total Battery Time The total battery time is shown in the top right corner (Figure 4-17) of the status screen to indicate the total battery remaining time. Figure 4-17: Total Battery Time 4.2.3.3 Battery Detection Four batteries can be connected to the AUPS-C20 power module at the same time. When the smart battery is connected to the AUPS-C20 power module, the AUPS Battery Status Monitor detects it and shows in the screen as Figure 4-18.
AUPS-C20 UPS Module Using The battery is being used. Charging The battery is being charged. Standby The battery is fully charged and ready to be used anytime. The battery temperature is above 60°C. The battery temperature is below 60°C. 4.2.4 Battery Information Click the BATTERY tab to view the information of the connected batteries. Click the battery number on the right side of the battery screen to display its battery information.
AUPS-C20 UPS Module 4.2.5 LAN Setting The LAN Setting page is where to configure the Remote LAN settings for power on/off remote control and battery monitoring. To save the modified parameters of this page, click the Save Config button. To load the default settings, click the Load Default button.
AUPS-C20 UPS Module 4.2.6 Setting Click the SETTING tab to enable/disable buzzer, LAN and automatic DC output (Figure 4-21). Figure 4-21: Application Setting Functions can be set in the SETTING tab include: Check to disable the buzzer that warns when the system is switching to use battery power. Check to enable the LAN for remote monitoring function. Check to enable the remote computer to turn the system power on or off.
AUPS-C20 UPS Module 4.3 Remote Control and Monitoring The AUPS-C20 can be controlled (power on/off) and monitored the battery status through a remote computer located in the same subnet with the AUPS-C20. To control and monitor the AUPS-C20 remotely, follow the steps below. Step 1: Connect the RJ-45 remote LAN connector on the I/O interface panel of the AUPS-C20 (Figure 4-22) to a local area network connector. Figure 4-22: RJ-45 Remote LAN Connector Step 2: In a remote computer, install the IEI REMOTE AP.
AUPS-C20 UPS Module Figure 4-23: IEI REMOTE AP Step 4: To access the web interface for advanced monitoring and functions, double click the IP address of the connected AUPS-C20 (Figure 4-24). Figure 4-24: IEI REMOTE AP – IP Address Step 5: Figure 4-25 shows in a web browser.
AUPS-C20 UPS Module Figure 4-25: Remote Management Web Interface - Status Step 6: To send an email to an administrator through the SMTP server, click Send E-mail button on the left. Fill out the information as indicated in Figure 4-26. Click the Send Message button to send the email. Figure 4-26: Remote Management Web Interface - Send Email Step 7: To configure the AUPS-C20 network setting, click the Configuration button on the left.
AUPS-C20 UPS Module Step 8: A window prompts for the user name and password. The default user name and password for the LAN setting page are: User name: admin Password: IEI Figure 4-27: Enter User Name and Password Step 9: The Board Configuration window appears. Configure the network settings and click the Save Config button. Incorrect settings may cause the board to lose network connectivity.
AUPS-C20 UPS Module Appendix A A Hazardous Materials Disclosure Page 38
AUPS-C20 UPS Module A.1 Hazardous Materials Disclosure Table for IPB Products Certified as RoHS Compliant Under 2002/95/EC Without Mercury The details provided in this appendix are to ensure that the product is compliant with the Peoples Republic of China (China) RoHS standards. The table below acknowledges the presences of small quantities of certain materials in the product, and is applicable to China RoHS only.
AUPS-C20 UPS Module Part Name Toxic or Hazardous Substances and Elements Lead Mercury Cadmium Hexavalent Polybrominated Polybrominated (Pb) (Hg) (Cd) Chromium Biphenyls Diphenyl (CR(VI)) (PBB) Ethers (PBDE) Housing X O O O O X Display X O O O O X Printed Circuit X O O O O X X O O O O O X O O O O X Fan Assembly X O O O O X Power Supply X O O O O X O O O O O O Board Metal Fasteners Cable Assembly Assemblies Battery O: This toxic or hazardo
AUPS-C20 UPS Module 此附件旨在确保本产品符合中国 RoHS 标准。以下表格标示此产品中某有毒物质的含量符 合中国 RoHS 标准规定的限量要求。 本产品上会附有”环境友好使用期限”的标签,此期限是估算这些物质”不会有泄漏或突变”的 年限。本产品可能包含有较短的环境友好使用期限的可替换元件,像是电池或灯管,这些元 件将会单独标示出来。 部件名称 有毒有害物质或元素 铅 汞 镉 六价铬 多溴联苯 多溴二苯 (Pb) (Hg) (Cd) (CR(VI)) (PBB) 醚 (PBDE) 壳体 X O O O O X 显示 X O O O O X 印刷电路板 X O O O O X 金属螺帽 X O O O O O 电缆组装 X O O O O X 风扇组装 X O O O O X 电力供应组装 X O O O O X 电池 O O O O O O O: 表示该有毒有害物质在该部件所有物质材料中的含量均在 SJ/T11363-2006 标准规定的限量要求以下。