AUPS Series Power Module User Manual MODEL: AUPS Series VESA Mount Intelligent UPS Module 12 V DC Input or 9 V–36 V DC Input Network Remote Management Support User Manual Page i Rev. 1.
AUPS Series Power Module User Manual Revision Date Version Changes May 7, 2014 1.01 Added Appendix A: Safety Precautions November 12, 2008 1.
AUPS Series Power Module User Manual Copyright COPYRIGHT NOTICE The information in this document is subject to change without prior notice in order to improve reliability, design and function and does not represent a commitment on the part of the manufacturer. In no event will the manufacturer be liable for direct, indirect, special, incidental, or consequential damages arising out of the use or inability to use the product or documentation, even if advised of the possibility of such damages.
AUPS Series Power Module User Manual Manual Conventions WARNING! Warnings appear where overlooked details may cause damage to the equipment or result in personal injury. Warnings should be taken seriously. Warnings are easy to recognize. The word “warning” is written as “WARNING,” both capitalized and bold and is followed by text. The text is the warning message. A warning message is shown below: WARNING: This is an example of a warning message.
AUPS Series Power Module User Manual NOTE: These messages inform the reader of essential but non-critical information. These messages should be read carefully as any directions or instructions contained therein can help avoid making mistakes. Notes are easy to recognize. The word “note” is written as “NOTE,” both capitalized and bold and is followed by text. The text is the cautionary message. A note message is shown below: NOTE: This is an example of a note message. Notes should always be read.
AUPS Series Power Module User Manual Table of Contents 1 INTRODUCTION.......................................................................................................... 1 1.1 AUPS SERIES OVERVIEW ........................................................................................... 2 1.2 AUPS SERIES UPS MODULE FEATURES ..................................................................... 2 1.3 EXTERNAL OVERVIEW ....................................................................................
AUPS Series Power Module User Manual 4 SOFTWARE APPLICATION..................................................................................... 21 4.1 INTRODUCTION......................................................................................................... 22 4.2 MONITORING DC POWER AND SMART BATTERY ...................................................... 22 4.2.1 Application Installation.................................................................................... 22 4.2.
AUPS Series Power Module User Manual List of Figures Figure 1-1: AUPS Series UPS Module ..........................................................................................2 Figure 1-2: AUPS Series Standard I/O Interface Connectors.....................................................3 Figure 1-3: AUPS-A10 Power Input Connector............................................................................4 Figure 1-4: AUPS-A20 Power Input Connectors........................................................
AUPS Series Power Module User Manual Figure 4-16: RJ-45 Remote LAN Connector...............................................................................31 Figure 4-17: IEI REMOTE AP .......................................................................................................32 Figure 4-18: IEI REMOTE AP – IP Address ................................................................................33 Figure 4-19: Remote Management Web Interface - Status ............................................
AUPS Series Power Module User Manual List of Tables Table 1-1: LED Indicators ..............................................................................................................6 Table 1-2: AUPS Series Specifications.........................................................................................7 Table 1-3: Battery Specifications ..................................................................................................8 Table 2-1: Package List Contents ..........................
AUPS Series Power Module User Manual Chapter 1 1 Introduction Page 1
AUPS Series Power Module User Manual 1.1 AUPS Series Overview Figure 1-1: AUPS Series UPS Module The highly efficient, high-performance AUPS Series UPS (Uninterruptible Power Supply) module installed with a Li-ion battery to provide stable 12 V output and uninterruptible power to the IEI AFOLUX series panel PCs. The UPS module also receives either 12 V input or a wide range of inputs between 6 V and 36 V DC.
AUPS Series Power Module User Manual 1.3 External Overview 1.3.1 I/O interface panel (Standard) The I/O interface panel of the AUPS Series (see Figure 1-2) has the following standard I/O interface connectors: 1 x 12 V DC output jack 1 x USB mini-B connector 1 x Network remote management port (RJ-45) 1 x DC output switch terminal block 1 x DC on/off button The standard external I/O interface connector panel is shown in Figure 1-2.
AUPS Series Power Module User Manual 1.3.1.1 AUPS-A10 Power Input Connector The AUPS-A10 has one power jack for +12 V DC input (Figure 1-3). Figure 1-3: AUPS-A10 Power Input Connector 1.3.1.2 AUPS-A20 Power Input Connectors The AUPS-A20 has one power jack and one terminal block for 9 V–36 V DC inputs (Figure 1-4).
AUPS Series Power Module User Manual 1.3.1.3 AUPS-B10 Power Input Connector The AUPS-B10 has one 4-pin power connector for +12 V DC input (Figure 1-5). Figure 1-5: AUPS-B10 Power Input Connector 1.3.1.4 AUPS-B20 Power Input Connectors The AUPS-B20 has one 4-pin power connector and one terminal block for 9 V–36 V DC inputs (Figure 1-6).
AUPS Series Power Module User Manual 1.3.2 LED Indicators The side panel of the AUPS Series has three LED indicators to indicate the power and battery status (Figure 1-7). Figure 1-7: AUPS Series LED Indicators All the LED statuses are listed in Table 1-1.
AUPS Series Power Module User Manual 1.4 AUPS Series Specifications The AUPS Series UPS module technical specifications are listed in Table 1-2. Model Name AUPS-A10 AUPS-A20 VESA Type VESA 75 mm x 75 mm AUPS-B10 AUPS-B20 VESA 75 mm x 75 mm VESA 100 mm x 100 mm Output Voltage +12 V +/-5% +12 V +/-5% +12 V +/-5% Power 60 W 60 W 100 W Input Voltage +12 V +9 V ~ +36 V +12 V +9 V ~ +36 V Battery Type Li-ion 2S2P Li-ion 2S2P Li-ion 4S2P Li-ion 4S2P Normal 7.4 V 7.4 V 14.8 V 14.
AUPS Series Power Module User Manual 1.5 Battery Specifications The AUPS Series comes with a Li-ion smart battery. Some of the Li-ion battery specifications are listed in Table 1-3. AUPS-A10/AUPS-A20 AUPS-B10/AUPS-B20 Battery Model BAT-LI-2S2P3800 BAT-LI-4S2P3800 Battery Type Li-ion Li-ion Nominal Capacity 3800 mAH 3800 mAH Nominal Voltage 7.4 V 14.8 V Max. Charge Voltage 8.4 V 16.8 V Cut Off Voltage 5.6 V 11.2 V 2A 2A 7.6 A 7.
AUPS Series Power Module User Manual 1.6 AUPS Series Dimensions 1.6.1 AUPS-A10/AUPS-A20 Dimensions The AUPS-A10 and AUPS-A20 dimensions are shown in Figure 1-8.
AUPS Series Power Module User Manual 1.6.2 AUPS-B10/AUPS-B20 Dimensions The AUPS-B10 and AUPS-B20 dimensions are shown in Figure 1-8.
AUPS Series Power Module User Manual Chapter 2 2 Unpacking Page 11
AUPS Series Power Module User Manual 2.1 Anti-static Precautions WARNING: Failure to take ESD precautions during the installation of the AUPS Series may result in permanent damage to the AUPS Series and severe injury to the user. Electrostatic discharge (ESD) can cause serious damage to electronic components, including the AUPS Series. Dry climates are especially susceptible to ESD.
AUPS Series Power Module User Manual 2.3 Unpacking Checklist NOTE: If some of the components listed in the checklist below are missing, please do not proceed with the installation. Contact the IEI reseller or vendor you purchased the AUPS Series from or contact an IEI sales representative directly. To contact an IEI sales representative, please send an email to sales@ieiworld.com.tw. 2.3.
AUPS Series Power Module User Manual 1 USB Type A to mini-B cable 1 Screw kit 2 Wall mount bracket 1 Utility software CD Table 2-1: Package List Contents Page 14
AUPS Series Power Module User Manual Chapter 3 3 Installation Page 15
AUPS Series Power Module User Manual 3.1 Anti-static Precautions WARNING: Failure to take ESD precautions during the maintenance of the AUPS Series may result in permanent damage to the AUPS Series and severe injury to the user. Electrostatic discharge (ESD) can cause serious damage to electronic components, including the AUPS Series. Dry climates are especially susceptible to ESD.
AUPS Series Power Module User Manual Anti-static Discharge: If a user open the top cover of the power module, to configure the jumpers or plug in added peripheral devices, ground themselves first and wear and anti-static wristband. 3.3 Installation and Configuration Steps The following installation steps must be followed. Step 1: Unpack the UPS module Step 2: Install the battery pack Step 3: Mount UPS module to the AFOLUX panel PC Step 4: Connect the UPS module to the AFOLUX panel PC Step 0: 3.
AUPS Series Power Module User Manual Figure 3-2: Top Cover Retention Screws (Top Panel) Step 2: Install the battery pack into the AUPS Series. Make sure the battery pack is connected to the battery connector on the board. (Figure 3-3) Figure 3-3: Battery Pack Installation Step 3: Secure the battery pack with two retention screws. Step 4: Replace the top cover. Step 0: 3.5 Mounting the AUPS Series To mount the AUPS Series onto the rear panel of the AFOLUX panel PC, follow the steps below.
AUPS Series Power Module User Manual the panel PC. Secure the mounting bracket to the panel PC with four retention screws (Figure 3-4). Figure 3-4: Mounting Bracket Installation Step 2: Place the AUPS Series onto the mounting bracket. Secure the AUPS Series to the bracket with three retention screws, one on the top panel and one on each side panel (Figure 3-5).
AUPS Series Power Module User Manual 3.6 Connecting the AUPS Series To support the UPS function to the panel PC, the AUPS Series must be connected to the power source and to the panel PC. Figure 3-6 shows the connections.
AUPS Series Power Module User Manual Chapter 4 4 Software Application Page 21
AUPS Series Power Module User Manual 4.1 Introduction The IEI AUPS Battery Status Monitor application detects the information of the smart battery and monitors the battery status. It is recommended to execute this AUPS application in Windows XP SP2 environment. 4.2 Monitoring DC Power and Smart Battery 4.2.1 Application Installation Follow the steps below to install the AUPS Battery Status Monitor application. Step 1: Insert the driver CD into the system. Open the x:\AUPS_Setup\ AUPS_SetupV1.4 directory.
AUPS Series Power Module User Manual Figure 4-2: Select Installation Folder Step 4: Click NEXT and the Installshield Wizard is ready to install the program (Figure 4-3). Figure 4-3: Ready to Install the Program Step 5: Click NEXT to continue. The Installing AUPS_Setup screen appears as the program is installed (Figure 4-4).
AUPS Series Power Module User Manual Figure 4-4: Installing AUPS Step 6: The Installation Complete window appears (Figure 4-5). Click Close to exit. Figure 4-5: Installation Complete Step 7: To launch the application, double click the shortcut (Figure 4-6) on the desktop.
AUPS Series Power Module User Manual 4.2.2 Status Information The IEI AUPS Battery Status Monitor application shows the DC power status and battery status (Figure 4-7). The following sections describe the status information in details. Figure 4-7: Status Information 4.2.2.1 DC Detection When the DC power is connected to the AUPS series power module, the AUPS Battery Status Monitor detects it and shows in the screen as Figure 4-8.
AUPS Series Power Module User Manual 4.2.2.2 Battery Detection When the smart battery is connected to the AUPS series power module, the AUPS Battery Status Monitor detects it and shows in the screen as Figure 4-9. Two batteries can be connected to the AUPS series power module at the same time. The second battery information is shown in the Battery A Detection section if connected. Figure 4-9: Battery Detection The battery is connected to the AUPS series.
AUPS Series Power Module User Manual Figure 4-10: Total Battery Time 4.2.3 Battery Information Click on the BAT. A tab to view the information of battery. The listed information includes battery type, capacity, output voltage, temperature, charging rate, discharging rate and battery status (Figure 4-11). The values listed are updated per second. Figure 4-11: Battery Information 4.2.
AUPS Series Power Module User Manual Figure 4-12: LAN Setting The LAN Setting page can also setup the user name and password for remote monitoring. To change the user name and password, click button. Enter the new user name and password (Figure 4-13). Click button to save the settings.
AUPS Series Power Module User Manual Figure 4-13: LAN Setting – Change Password 4.2.5 Setting Click on the SETTING tab to select the COM port, enable/disable buzzer, LAN and DC output (Figure 4-14).
AUPS Series Power Module User Manual Figure 4-14: Application Setting When the AUPS Battery Status Monitor application starts up, it automatically scans all COM port (COM1–COM16) and shows the valid COM port. Figure 4-15 shows the AUPS application is communicating with AUPS Series through COM 6. To change the serial port to communicate, select a proper port number from the list and click Connect. Before changing, please make sure the selected serial port is not used by other devices.
AUPS Series Power Module User Manual Other functions can be set in the SETTING tab include Check to disable the buzzer that warns when the system is switching to use battery power. Check to enable the LAN for remote monitoring function. Check to enable the remote computer to turn the system power on or off. (This function is not available at this stage.) Set the battery capacity parameter for the system to shut down automatically.
AUPS Series Power Module User Manual Step 2: In a remote computer, install the IEI REMOTE AP. Double click the setup.exe file in the x:\Other\AUPS REMOTE AP directory. Follow the steps to install the IEI REMOTE AP. After installation, launch the AP. If there is a problem to launch the tool, execute the dotnetfxRedist20.exe first (located in the same directory of the driver CD). Step 3: The IEI REMOTE AP tool appears (Figure 4-17).
AUPS Series Power Module User Manual Figure 4-18: IEI REMOTE AP – IP Address Step 5: Figure 4-19 shows in a web browser. Figure 4-19: Remote Management Web Interface - Status Step 6: To send an email to an administrator through the SMTP server, click Send E-mail button on the left. Fill out the information as indicated in Figure 4-20. Click the Send Message button to send the email.
AUPS Series Power Module User Manual Figure 4-20: Remote Management Web Interface - Send Email Step 7: To configure the AUPS Series network setting, click the Configuration button on the left. Step 8: A window prompts for the user name and password. The default user name and password for the LAN setting page are: User name: admin Password: IEI If the user name and password has been change as described in Section 4.2.4, enter the new user name and password.
AUPS Series Power Module User Manual Step 9: The Board Configuration window appears. Configure the network settings and click the Save Config button. Incorrect settings may cause the board to lose network connectivity. Recovery options are provided on the next page.
AUPS Series Power Module User Manual Appendix A A Safety Precautions Page 36
AUPS Series Power Module User Manual DANGER! 1. Disassemble and Reconstruction “Do not disassemble or reconstruct battery” The battery pack has safety function and protection circuit to avoid the danger. If they have serious damage, it will cause the generating heat, smoke, rupture or flame. 2. Short-circuit “Do not short-circuit battery” Do not connect the + and – terminals with metals (such as wire). Do not carry or store the battery with metal objects (such as wire, necklace or hairpins).
AUPS Series Power Module User Manual are cases that it will be overcharged or the abnormal chemical reaction will occur in cells. It caused the generating heat, smoke, rupture or flame. 8. Penetration “Do not drive a nail into the battery, strike it by hammer, or tread it” As the battery might be broken or deformed and then it will be short-circuited, it caused the generating heat, smoke, rupture or flame. 9.
AUPS Series Power Module User Manual 15. Inappropriate Use for Other Equipment “Do not use battery for other equipment” If the battery is used for unspecified equipment, it will deteriorate its performance and cycle-life. At worst, abnormal current will flow or battery may generate heat, smoke, rupture or flame. 16. Leakage “Do not touch a leaked battery directly” in case the leaked electrolyte gets into eyes, wash them with fresh water as soon as possible without rubbing eyes.
AUPS Series Power Module User Manual 6. Rust, Changing Color and Deformation “Do not use an abnormal battery” In case the battery has bad smell or is generated its changing color or deformation or causes something wrong in using (includes charging and storage), let it take out from equipment or charger and do not use it. If an abnormal battery is used, it will generate, smoke, rupture or flame. CAUTION: 1.
AUPS Series Power Module User Manual 8. Keep Battery Away From Children Keep the battery out of the reach of younger children. And also, pay attention when the battery is taken out from the charger or equipment by little children. 9. Leakage If the skin or cloth is smeared with liquid from the battery, wash with fresh water. It may cause the skin inflammation.
AUPS Series Power Module User Manual Appendix B B Hazardous Materials Disclosure Page 42
AUPS Series Power Module User Manual B.1 Hazardous Materials Disclosure Table for IPB Products Certified as RoHS Compliant Under 2002/95/EC Without Mercury The details provided in this appendix are to ensure that the product is compliant with the Peoples Republic of China (China) RoHS standards. The table below acknowledges the presences of small quantities of certain materials in the product, and is applicable to China RoHS only.
AUPS Series Power Module User Manual Part Name Toxic or Hazardous Substances and Elements Lead Mercury Cadmium Hexavalent Polybrominated Polybrominated (Pb) (Hg) (Cd) Chromium Biphenyls Diphenyl (CR(VI)) (PBB) Ethers (PBDE) Housing O O O O O O Display O O O O O O Printed Circuit O O O O O O O O O O O O O O O O O O Fan Assembly O O O O O O Power Supply O O O O O O O O O O O O Board Metal Fasteners Cable Assembly Assemblies Battery O: This
AUPS Series Power Module User Manual 此附件旨在确保本产品符合中国 RoHS 标准。以下表格标示此产品中某有毒物质的含量符 合中国 RoHS 标准规定的限量要求。 本产品上会附有”环境友好使用期限”的标签,此期限是估算这些物质”不会有泄漏或突变”的 年限。本产品可能包含有较短的环境友好使用期限的可替换元件,像是电池或灯管,这些 元件将会单独标示出来。 部件名称 有毒有害物质或元素 铅 汞 镉 六价铬 多溴联苯 多溴二苯 (Pb) (Hg) (Cd) (CR(VI)) (PBB) 醚 (PBDE) 壳体 O O O O O O 显示 O O O O O O 印刷电路板 O O O O O O 金属螺帽 O O O O O O 电缆组装 O O O O O O 风扇组装 O O O O O O 电力供应组装 O O O O O O 电池 O O O O O O O: 表示该有毒有害物质在该部件所有物质材料中的含量均在 SJ/T11363-2