User guide
AFL2-W21A/AB-H61
Page 135
1 (PWM)
2 (PWM)
4 (PWM)
8 (PWM)
16 (PWM)
32(PWM)
Fanless Temp. Overwrite Control [Enabled]
Use the Fanless Temp. Overwrite Control option to enable or disable Fanless Temp.
Overwrite control function. The Temperature of Fanless can be set after this item has
been enabled.
Enabled
Enables the Fanless Temp. Overwrite control function.
Disabled DEFAULT
Disables the Fanless Temp. Overwrite control function.
Temperature Of Fanless [32 C]
NOTE:
If the Temperature of Fanless is enabled, the fan will only turn on when
the Environment Temperature 1 reaches to the temperature set in the
following Temperature of Fanless option.
For safety reason, the fan will turn on automatically to cool down the
system when the CPU temperature exceeds 80 ºC, no matter the
Temperature of Fanless is enabled or not.
Use the Temperature Of Fanless option to configure default temperature setting. When
the environment temperature is lower than default temperature setting, the fan will be
switched off. When the environment temperature is higher than default temperature
setting, the fan will be switched on. (The environment temperature depends on the
Environment Temperature 1.) A list of available options is shown below:
Disabled
Disabled the Temperature Of Fanless function