Datasheet
Sensor Characteristics
Sensor Description
Sensor type Pressure Sensitive High Dynamic Single Sensor
Typical applications/devices Dynamic user interface devices and high-dynamic
pressure sensors for in-shoe measurements
Number of active areas/cells 1
Dimensions and available connectors See layout drawings on the following pages
Manufacturing Tolerances
According to DIN 7151 IT 14
Thickness Nominal value +/- 12 %
Total manufacturing tolerance +/- 0.8 mm
Base Materials
Topside substrate
Acrylic
Backside substrate
Backing adhesive Acrylic
Operating Parameters
Standby resistance (no load)
Typical activation resistance range
for a pressure range of 20 mbar - 7 bar. See Typical Response Curve on
page 24
Typical conductor lead resistance
Typical lifetime when used according to applica-
tion advice
Typical sensor response time on single activation 2-3 ms (mechanical)
Current density < 1 mA/cm
2
(of activated area)
Parasitic capacitance < 1 nF
Power dissipation < 1 mW/cm
2
(of activated area)
Operating Conditions
Nominal operating voltage
Operating temperature range -40 to +85 °C (-40 to 185 °F)
Operating humidity range
Standard Test Criteria at Time of Delivery
Standby resistance
Measuring device IEE overpressure membrane tester
HD-FSR
27
CIS