Instruction Manual
User Guide for Battery Management System Ver4.2
Page 55/75 IDX Company, Ltd.
3) Battery data after the second full charge
* The screen displays charge data in the order in which it was obtained, beginning with the most
recent data shown at the top.
* Because the date of the first full charge is recorded in Date of First Full Charge, the charge data
shown in Charge Record applies to the second charge and onward.
* In relation to Number of Cycles, the BMS counts as one cycle any charge that takes place after a
continuous discharge of 10% or more of the current capacity.
5. Necessary conditions for the recording of Charge and Discharge Data
1) Discharge data
The system will record data of all continuous discharges of one minute or more with a load of 3 W or
above. To enable correct recording, the load must be removed after each discharge.
2)Charge data
Data will be recorded after a full charge.
* Only the three most recent charges (or discharges) can be recorded in the battery or BMS-VR. Recording
the fourth charge (or discharge) will overwrite the data of the oldest charge (or discharge).
A record of the second charge is
shown in Charge Record.
Cycles are counted in Number of Cycles.