User's Manual

11
EN
5. Press
to conrm and continue to next setting
OR
Touch anywhere on the screen (except tool bar / area) to conrm
and exit.
To enable / disable alarms:
1. Press desired area to activate.
2. Press
to display set HI / LO alarm.
3. Press
to turn alarm on or off.

- - indicates alarm is not set / disabled.

Clock alarm sound is different from weather alarms to allow for easy
differentiation by user.
To silence any alarm:
Press anywhere on the touch panel.
OR
The alarm automatically turns off after 2 minutes.

When alarm is on, the channel of triggered alarm will be ashed and alarm
sound lasts for 2 minutes.
BACKLIGHT
Press anywhere on the touch panel to activate the backlight for 8 seconds.
OR
If the main unit is powered by power adapter, switch the LIGHT to ON in the main
unit compartment. The light will be on until you switch it OFF.

You need to take off the battery compartment cover to do switching.
RESET
Main unit:
 
Press RESET to return to the default settings.

You need to take off the battery compartment
cover to do switching.
Transmitter box:
Press RESET to remove the record of the calibrated
wind direction.
MAINTAINANCE
Each sensor of this kit has a durable plastic casing that should retain its luster for
many years. It is better to do regular maintenance to keep the sensors with high
accuracy every half year. Do cleaning the casing only with a soft cloth slightly
dampened with water or a mild soap. Please use screw drivers or wrench to take
some parts off if necessary.
Electrical storms can sometimes cause power surges harmful to electronic
equipment. For your own safety, take caution when using the main unit or doing
maintenance during storms.
To Maintain the Thermo/Hygro Sensor (THGN300)
1. Remove the rain collector from the rain gaug.
2. Unscrew the three type B screws from the
rain gauge.
3. Unscrew the three screws from the bottom
of the thermo/hygro sensor casing.
4. Take off the white sensor protective cap by
squeezing its two sides with some pressure.
5. Extract the inner cap and lter screen from
the outer cap.
6. Clean the lter screen and casing
with water.
7. Install all the parts until they are
entirely dried.

If the temperature and humidity readings are still strange and inaccurate,
you need to consider replacing this sensor, please contacting our customer service
for the details.
To Maintain the Rain Gauge (PCR300)
Clean the hole of the rain collector and the
tipping bucket for maintaining accuracy is
very important.
1. Check the lter regularly and ensure it is
not fully covered by the leaves or other
objects. Clean the hole of the rain
collector by water.
2. Pulling bucket holder a little distance to
take off the tipping bucket for cleaning the
dirt by water. Ensure the surface of the
tipping bucket without droplet before
returning to the bucket holder, which
affects the accuracy.
3. Clean the drain holes on the rain gauge base.

The user should unplug the rain sensor before cleaning. Otherwise, the
tipping bucket still makes data.
To Maintain the Wind sensor (WGR 300)
If the wind cup doesn’t spin in the wind or does not spin as fast as they should
1. Remove the wind cup and clear out all bugs, spider webs or debris.
2. Ensure the O-ring surrounding the shaft keeps over 0.3mm gap from plastic. If
there is any friction or interference between the O-ring and plastic, it will make
the wind cup spinning slowly and affect the reading accuracy of wind speed.

Do not apply any uid lubricant on the shaft and bearing. It probably breaks
the inner electronic components.
TROUBLE SHOOTING
Problem Symptom Remedy
Barometer Strange readings Check altitude setting on the main unit.
Wind sensor No updates of the
wind direction
Check the wind vane.
Display dashes on
main unit
1. Check the connections.
2. Check the channel setting.
3. Check the pairing successful or not.
Rain sensor No readings 1. Check the cable tie on the tipping
bucket to be cut away or not.
2. Check the balance indicator.
3. Check the plastic lter in rain collector.
4. Check the connections.
Strange readings 1. Check the plastic lter in the rain collector.
2. Check the balance indicator.
Temp/hygro
sensor
Display dashes 1. Check the connections.
2. Check the pairing.
3. Check the channel setting.
No outdoor temp/
hygro readings
1. Check the rechargeable battery in
transmitter box.
2. Check the power adapter connection
and main unit batteries status.
3. Do maintenance for the sensor.
Calendar Strange date /
month
1. Change language.
2. Check the calendar setting.
Clock Cannot adjust
clock
Disable radio-controlled clock.
Cannot
auto-synchronize
1. Check batteries status.
2. Reset the main unit.
3. Manually activate radio controlled clock.
Sunrise/
Sunset
Strange readings 1. Set longitude/latitude.
2. Check the daylight saving time setting.
Transmitter
box
LED light(s) do not
ash
1. Check the switch.
2. Check the polarity of the
rechargeable battery.
3. Check the connection of the solar panel.
Sensors
pairing
Time is too long 1. Adjust the antennas to be parallel.
2. Reset the pairing switch (switch off
then on again).