User's Manual
Status
Normal
Battery
Low
Battery
Critical
Battery
Power
on
On in
green
for
1
second
On in
green
for
1
second
Flashes in
red
three times
per
minute.
Start
mode
(pinging for
the
meter)
OFF
OFF
Flashes in
red
three times
per
minute.
Communicating
with
Meter/Hub
Flashes
in
green
once
per
second
Flashes
in
green and
red
alternatively
Flashes in
red
three times
per
minute.
Transmission
completed
Blue is on
for
5
seconds
Flashes
in
blue and
red
alternatively
Flashes in
red
three times
per
minute.
Transmission
fails
/
Lost
Flashes
in
red
Flashes in
red
very
quickly
Flashes in
red
three times
per
minute.
• Hold the Wireless SmartClip and pull the meter from the
left-
hand side with some
pressure.
OPERATION
After the Wireless SmartClip is installed onto the meter, you need
to
turn on the Wireless SmartClip to ensure the transmission
works.
Make sure you power up the coagulation meter in priority of
turning
on the Wireless
SmartClip.
The effective distance between a counterpart station, such
as
a
hub, and the coagulation meter should be not far from each
other
more than 10 meters or 32.8
feet
data from the Wireless SmartClip. Please wait until
the
connection has been re-established
automatically.
• Note: If you measured your prothrombin time (PT)
without
data transmission, the collected PT values will
be
automatically transmitted once a data connection will
be
established
again.
Turn off the Wireless
SmartClip:
• Slide the switch to OFF after having ensured a
successful
data
transmission
.
The effective distance between a counterpart station,
such
TM
Turn on the Wireless
SmartClip:
as a
2net
hub, and the Wireless SmartClip should be not far
from
• Slide the switch to ON. LED indicator lights up briefly
in
green (given a normal battery
status).
• Run a prothrombin time (PT) measurement with the
Roche
CoaguChek XS meter, as described in the operating
manual
of the
meter.
• Once the PT measurement result is shown on the display
of
the CoaguChek XS meter, please do not turn off the
meter,
until the data transmissions will start automatically (within
60
seconds), which will be indicated by a green flashing
LED.
• Ensure that the blue LED indicates that data
transmission
was successful (steady or flashing according to the
table
below).
• Once you saw the blue LED, your PT data has
been
transmitted
successfully.
• If there is no blue LED, please make sure that the
receiving
device (e.g. 2net
TM
hub) is turned on and able to receive
the
each other more than 10
meters.
LED
INDICATOR