User's Manual
IDS Ingegneria Dei Sistemi S.p.A.
N doc.: MN/2011/067 – Rev. 1.0
17 / 29
3. WORKING PROCEDURE
Step 1: Assemble the system and place the antenna on the surface to be investigated).
Fig. 3.1 – Surveying with the system
Step 2: Start the K2 SW, perform the calibration and set the acquisition parameters
Step 3: Position the antenna on the initial preset coordinate in the L (or T) direction
Step 4A (Standard System): Press one of the START buttons placed on the handle or
directly on the antenna
Step 4B (US-Canada System): Press one of the START buttons placed on the antenna
and keep it pressed. Releasing the button, will stop the collection after 10 sec.
Step 5A (Standard System): Insertion of User Markers during scanning is performed by
rapidly pressing the START button.
Step 5B (US-Canada System): Insertion of User Markers during scanning is performed
by rapidly releasing and pressing again the START button.