User's Manual
IDS Ingegneria Dei Sistemi S.p.A. N°doc: MN/2009/070 - Rev. 1.1
IBIS-L v.02.00 - User manual
56 / 65
All information contained in this document is property of IDS. All rights reserved.
4.3 Dismantling the measurement site
The following procedure should be followed to remove the instrument from the
measurement site:
1. disconnect the cables connecting the IBIS sensor to the linear scanner,
unscrewing the rings and pulling them out from the sensor connectors;
2. disconnect the cables connecting the linear scanner to the power supply module,
unscrewing them then pulling them out;
3. screw the protective caps onto the two IBIS connectors and the two flexible linear
scanner connectors;
4. unscrew the knobs on the dovetail guides;
5. remove the IBIS sensor and place it in the case;
6. remove the trolley, loosening the four knobs that block the dovetail guides that fix
it to the linear scanner and position it in its space in the IBIS-L box;
7. tighten the knobs back onto the dovetail guides to endure they are not lost or
damaged during transportation;
8. unscrew the three M16 nuts mounted on the studs at the two ends of the module;
9. remove the washers, disc springs and spherical thrust bearings from the three
studs;
10. unscrew the M8 lock nuts and the nuts to free the linear scanner;
11. replace all the DEM spacers back into the IBIS-L box as described in par. 4.1.1;
12. lift the linear scanner and place it in the IBIS-L box;
13. close the case after checking all parts have been packed and wing nuts tightened;
14. replace all cables, the optical telescope and the antennas in the IBIS-L trolley
case.