User's Manual
IDS Ingegneria Dei Sistemi S.p.A. N°doc: MN/2009/070 - Rev. 1.1
IBIS-L v.02.00 - User manual
38 / 65
All information contained in this document is property of IDS. All rights reserved.
(a) (b)
Fig. 3.24 - (a) battery housing area, (b) power supply module connector area with the
ground screw highlighted
The input voltage must be regulated to correspond to the voltage available on site. This is
done by setting the control on the transformer found behind the front panel as shown in
the following pictures.
1. Make sure you disconnect the
power supply module from the
mains supply before starting the
following procedure.
2. Open the front panel. The
transformer is located in the top
right corner.
WARNING:
ADJUST THE TRANSFORMER VOLTAGE SETTING
IT TO
THE VOLTAGE AVAILABLE ON SITE
BEFORE
CONNECTING THE
APPARATUS TO THE MAINS SUPPLY