4.2.4 Connecting the position sensor
Fig. 4.11 Connecting the position sensor
The system position sensor is situated inside one of the trolley
wheels and turns in unison with it (Fig. 4.11).
The sensor measures all movements of the Detector Duo from
its starting point, which coincides with the system centerpoint
(which is the center of the antenna).
The sensor cable has to be connected to the WHEEL port (1) on
the Control Unit
.
4.2.5 Removing the trolley wheels
If the wheels need to be removed for storage, press the black
button labelled PRESS (indicated by the arrow) to the side of
the wheel and pull the wheel outwards.
To reinsert the wheel onto the axis, it is sufficient to push it into
the support until the automatic block clicks into place (Fig.
4.12)
1