User's Manual

IDS Ingegneria Dei Sistemi S.p.A. N doc: MN/2009/028 - Rev. 1.1
DETECTOR DUO SYSTEM User manual
22
/
74
All information contained in this document is property of IDS. All rights reserved
3.1.3.1 Charge level and battery replacement
When the spy light is lit next to the power supply port on the radar,
this indicates that the system is powered: if it is not lit, this means that
either the cable is not connected correctly or that the battery is flat
(less than 10V). The battery has an autonomy of around 12 hours.
When the battery runs, down the instrument must be switched off,
another battery connected, and the system can be started up again. A
flat battery can be completely recharged in around 3 hours with the
appropriate battery charger (see Fig. 3.9 right). A software message on
the PC informs the user of the battery charge level with a BATT
button (see Fig. 3.9 left), which changes color as follows:
Green if the battery is fully charged,
Yellow if it is semi-charged,
Red if the battery is flat.
Fig. 3.9 Battery status signal (left) and the battery charger (right)