User's Manual
IDS Ingegneria Dei Sistemi S.p.A. N doc: MN/2009/028 - Rev. 1.1
DETECTOR DUO SYSTEM – User manual
20
/
74
All information contained in this document is property of IDS. All rights reserved
Fig. 3.6 – Battery cable connection for the notebook PC and the DAD, switch on button
(red)
Press the red button to switch on the DAD control unit (Fig. 3.6). This
button has to be kept pressed until the blue on switch lights up. If the
DetectorDuo software is not activated within 30 seconds, the indicator
light will start to flash. As soon as the DetectorDuo software is
activated the indicator light stops flashing and appears a constant blue
light. If, however, the Software is not activated within about 2 minutes
30 seconds, the DAD unit will automatically shut down. Once the
DetectorDuo software has been shut down, the indicator will flash for
about 30 seconds and will automatically shut down after 2 minutes.
GENERAL CHARACTERISTICS OF THE CONTROL
UNIT
NUMBER OF CONNECTABLE
ANTENNAS
2
VOLTAGE
12V +/- 10%
ENVIRONMENT FEATURES
IP65
PANEL CONNECTORS
LAN, BATTERY, ANT.1,
WHEEL
ABSORBED POWER
8W (1 antenna)
OPERATING TEMPERATURE
-10 / +40 °C
Tab. 3.1 – Control Unit characteristics