Fig. 4-11 – Sequence of 2 scans using a 2x2 pad
4.2.2 “Manual” Mode
Steps 1-4: Follow the same procedure described for "Automatic"
mode above.
Step 5: Acquis ition starts when you press the START button,
independently of the position of the first horizontal line encountered.
Step 6A (Standard System): Insertion of User Markers during
scanning is performed by rapidly pressing the START button.
Step 6B (US System): Insertion of User Markers during scanning is
performed by rapidly releasing and pressing again the START
button.
Step 7A (Standard System): The scan is STOPPED by keeping the
START button pressed
Step 7B (US System): The scan is STOPPED by releasing the START
button
NO TE!
The system keeps control of data quality (Tolerance
) in both
Automatic and Manual mode. In fact, if this tolerance is
respected, a confirmation acoustic signal is activated; if the
tolerance exceeds the pre-
set percentage during the scan,
an error acoustic signal is heard, the scan isn't saved and you
have to repeat it.