User's Manual

IDS Ingegneria Dei Sistemi S.p.A. Protocol: MN/2005/038 - Rev. 1.2
ALADDIN SK2 STRUCTURE KIT User
Manual
28 / 32
Fig. 4-10 START buttons
Step 5: Move the antenna in the pre-established direction; acquisition
will start as soon as the optical detector crosses the first horizontal
line.
Step 6: If you have pre-set "Auto Marker", each time the antenna
crosses a horizontal line, the system will insert a User Marker on the
scan.
Step 7: The scan will be automatically STOPPED as soon as the
optical detector encounters the last horizontal line pre-set by the
operator on the basis of the set scan Length.
Step 8: Continue the procedure described from step 3 onwards on the
next pre-set coordinate.
WARNI NG!
There is one particular case where you must pay attention:
if you use a 2x2 pad, the optical detector must carefully
follow a thick line f
ollowed by a fine line, the fine lines
being indicated with the extension F (see for example Fig.
4-11 which shows increasing coordinates (e.g. 1, 1F, 2, 2F
and so on). In Automatic
mode, you have to keep alignment
under control during scanning, making use
of the laser
pointer.