The Aladdin field consists of the following parameters: ·
Automatic: an automatic acquisition mode in which once the
other parameters have been set, it is sufficient to press start,
stop and any automatic user markers, positioning the system
just before the horizontal line shown on the pad. This mode
contains automatic data quality control (see the Tolerance
field later on).
Manual: in this mode, once you start, the acquisition is
performed independently of the position of the antenna with
respect to the pad. This mode also contains automatic data
quality control (see the Tolerance field later on).
Manual (no check): this acquisition mode has no type of
automatic data quality control, and leaves you free to acquire
data as you wish. In this case, the system limits itself to
providing an acoustic warning if the system is not following
the pre-established scan path. It is also possible to make
acquisitions without using the optical reader.
Auto marker: this sets an automatic user marker each time
the antenna crosses a horizontal line on the pad
Carpet grid: this represents the size of each square that the
optical detector signals with user markers on the pad; e.g.
2cm represents a 2x2cm square, while 4cm represents a
4x4cm square and so on.
Acquisition:
Length: this represents the length of the pass you intend
to perform on the pad..
Total scans: this represents the total number of passes
that you intend to perform starting from the initial
coordinate indicated on the pad.
Start coordinate: this represents the initial acquisition
coordinate shown on the pad..
Tolerance (% sweep out): this is the factor that controls
the quality of acquired data; this factor controls how
much road is covered by the antenna with respect to the
pre-set value and if the path length is greater than your
user set percentage error. In Automatic mode, if this value