9. Specifications
•
Standard Specifications (200V Class)
Voltage Class 200V single- / 3-phase
Model
CIMR-V7*C
‰‰‰‰
3-phase 20P1 20P2 20P4 20P7 21P5 22P2 23P7 25P5 27P5
Single-phase B0P1 B0P2 B0P4 B0P7 B1P5 B2P2 B3P7 - -
Max. Applicable Motor Output kW* 0.1 0.25 0.55 1.1 1.5 2.2 3.7 5.5 7.5
Output
Characteristics
Inverter Capacity (kVA) 0.3 0.6 1.1 1.9 3.0 4.2 6.7 9.5 13
Rated Output Current (A) 0.8 1.6 3 5 8 11 17.5 25 33
Max. Output Voltage (V)
3-phase, 200 to 230V (proportional to input voltage)
Single-phase, 200 to 240V (proportional to input voltage)
Max. Output Frequency (Hz) 400 Hz (Programmable)
Input
Current (A)
(3-Phase) 1.1 1.9 3.9 6.4 11.0 15.1 24.0 33.0 39.6
(Single-Phase) 1.8 3.7 7.4 12.8 20.5 24.0 40.0 - -
Power
Supply
Rated Input Voltage and
Frequency
3-phase, 200 to 230V, 50/60Hz
Single-phase, 200 to 240V, 50/60Hz
Allowable Voltage Fluctuation -15 to +10%
Allowable Frequency Fluctuation
±
5%
Control Characteristics
Control Method Sine wave PWM (V/f control/voltage control selectable)
Frequency Control Range 0.1 to 400Hz
Frequency Accuracy
(Temperature Change)
Digital reference:
±
0.01% (-10 to +50
°
C)
Analog reference:
±
0.5% (25
±
10
°
C)
Frequency Setting Resolution
Digital reference:
0.01Hz (less than 100Hz) / 0.1Hz (100Hz or more)
Analog reference: 1 / 1000 of max. output frequency
Output Frequency Resolution 0.01Hz
Overload Capacity 150% rated output current for one minute
Frequency Reference Signal
0 to 10VDC (20k
Ω
), 4 to 20mA (250
Ω
), 0 to 20mA (250
Ω
)
pulse train input, frequency setting potentiometer
(Selectable)
Accel/Decel Time
0.00 to 6000 sec.
(accel/decel time are independently programmed)
Braking Torque
Short-term average deceleration torque‡
0.1, 0.25kW (0.13HP, 0.25HP): 150%
0.55, 1.1kW (0.5 HP, 1HP): 100%
1.5kW (2HP): 50%
2.2kW(3HP) or more: 20%
Continuous regenerative torque: Approx. 20% (150% with
optional braking resistor, braking transistor built-in)
V/f Characteristics Possible to program any V/f pattern
*
Based on a standard 4-pole motor for max. applicable motor output.
‡
Shows deceleration torque for uncoupled motor decelerating from 60Hz
with the shortest possible deceleration time.