Instruction Manual
100
Register No. bit Description
002AH
Alarm Contents
0 Operator stop (STP)
1 Sequence error (SER)
2 FWD - REV command simulation input (EF)
3 External baseblock (BB)
4 Overtorque detection (OL3)
5 Cooling fin overheat (OH)
6 Main circuit overvoltage (OV)
7 Main circuit undervoltage
8 Cooling fan fault (FAN)
9 Communication error
A Option card communication error (BUS)
B Not used
C Inverter overheat prediction (OH3)
D PID feedback loss (FBL)
E Emergency stop (STP)
F Communication waiting (CALL)
002BH
Sequence input
0 Terminal S1 1 : Closed O : Open
1 Terminal S2 1 : Closed O : Open
2 Terminal S3 1 : Closed O : Open
3 Terminal S4 1 : Closed O : Open
4 Terminal S5 1 : Closed O : Open
5 Terminal S6 1 : Closed O : Open
6 Terminal S7 1 : Closed O : Open
7-F (Not Used)
002CH
Inverter status
0 Run 1 : Run
1 Zero - speed 1 : Zero - speed
2 Frequency agreed 1 : Agreed
3 Minor fault (Alarm is indicated)
4 Frequency detection 1 1: Output frequency
≤
(n095)
5 Frequency detection 2 1
:
Output frequency
≥
(n095)
6 Inverter operation ready 1 : Ready
7 Undervoltage detection 1 : Under Voltage detection
8 Baseblock 1 : Inverter output base block
9 Frequency reference mode
1 : Other than communications
0 : Communications
A Run command mode
1 : Other than communications
0 : Communications
B Overtorque detection 1 : Detection or overtorque fault
C (Not used)
D Fault restart
E Fault (Including MEMOBUS communications timeover) 1 : Fault
F MEMOBUS communications timeover 1 : Timeover
002DH
0 MA “ON” 1 : Closed 0 : Open
1 P1 “ON” 1 : Closed 0 : Open
2 P2 “ON” 1 : Closed 0 : Open
3-F
(Not used)