Integration Manual

uTrust 5501 F HF – OEM Integration Manual
Version: 1.1 Page 4 of 5
1 Scope of the document
This manual provides information for OEMs that integrate the uTrust 5501 F HF into their own
products.
2 Identiv uTrust 5501 F HF module
Identiv uTrust 5501 F HF is an USB based contactless card reader module. The reader
connects to host via USB 2.0 Full speed interface. It supports ISO14443 and ISO15693 cards
in HF mode. The information in this manual applies to the device model number listed below
along with its FCC ID and ISED ID:
Part Number Product Name FCC ID ISED ID
905567-3 uTrust 5501 F HF MBPUT5501F-01HF 7485A-5501F01HF
3 Host Communication Interface
Host communication is through the 1x5 header marked USB host.
Pinouts for USB host connector is as below:
PIN #
Signal
1 Vbus
2
D
-
3 D+
4 GND
5 Shield
The mating connector/receptacle for the header is TE Connectivity 440129-5
4 Integration Guidelines
1. This module is limited to OEM installation only.
2. Module complies with FCC Part 15.225, FCC Part 15.209, FCC Part 15.207 and RSS-
210.
3. End Product Labeling: When the module is installed in host device, the FCC ID label must
be visible through a window on the final device or it must be visible when an access
panel, door or cover is easily removed. If not, a second label must be placed on the
outside of the final device that contains the following text:
“Contains FCC ID: MBPUT5501F-01HF”. The FCC ID can be used only when all FCC
compliance requirements are met.
For ISED the second label should include Contains IC: 7485A-5501F01HF”. The ISED
ID can be used only when all other ISED compliance requirements are met.
4. Installation: The module must be installed such that 10 cm distance is maintained
between the integrated antenna and users.
5. The end user manual shall include all required regulatory information/warning as shown in
this manual.
6. There are no special testing modes for the module. When the module is powered it
automatically start scanning at 13.56 MHz (ASK) looking for tags. When a tag that
operates at same frequency and technology responds, the module locks onto it; the
module would not change to other frequency or technology until the tag leaves the field or
stops responding.