User's Manual
Table Of Contents
Key Value Description
min max default unit type
Scan
ScanMode 0 2 1
enum 0...Host Only no cont. Sequence
1...Continuos Mode
2...Input1 Mode
ScanSlotSelect 0 16 5
uint 2^x Number of Slots
ScanNum 0 32767 1
uint Number of sequences Input1 mode
ScanPause 0 32767 10 0.1
sec
uint Pause after a sequence
Blink
BlinkEnable 0 1 0
bool 1...All new Tags in field BLINK once
Read Data
ReadEnable 0 1 0
bool 1...Enable read data from tags
ReadAddress 0 32767 256
uint Start Address to read data
ReadNum 1 32 12
uint Number of byte to read
ReadBoost 0 20 6 dB int Power factor for read operation
ReadRetries 0 60 3
uint Number of retries
Tag Power Saving
PowSaveEnable 0 1 0
bool 1...All actual Tags in field Power save
PowSaveMode 0 2 0
enum 0...Sleep
1...Mute ( only for i-Dx)
2...Both
PowSaveDuration 0 255 2 sec uint How long the Tag should save power
Detection
DetectTagType 0 2 0
enum 0...i-Qx
1...i-Dx
2...Both
Note: i-Dx does not work in this version!
DetectMode 0 2 0
enum 0...Normal Detection
1...Maximum Level Detection
2...In/Out
DetectDuration 0 32767 5 sec uint Time for Max Level to detect a maximum
DetectInhibit 0 32767 10 sec uint How long a tag have to be out of field to be
cleared
Event Message
EventMsgEnable 0 1 0
bool 1...enable Events
EventRnTag 0 2 0
enum 0...When a Tag enters the field
1...When a Tag leaves the field
2...Both
EventRnInput1 0 3 0
enum 0...No Event
1...Rising Edge
2...Falling Edge
3...Change
EventRnInput2 0 3 0
enum
EventRnInput3 0 3 0
enum
EventRnInput4 0 3 0
enum
EventCntIPortID 0 1 0
bool Send i-PORT ID
EventCntDateTim
e
0 1 0
bool Send Date and Timed (UTC)
EventCntTagStat 0 1 0
bool Send Status of Tag
EventCntFStr 0 1 0
bool Send Field Strength Info