i-Q350 RCM SensorSMART™ Installation and Operation Manual VISIBILITY DELIVERED.
i-Q350 RCM USER MANUAL Proprietary Notice This document contains confidential information proprietary to IDENTEC SOLUTIONS and may not be used or disclosed to other parties in whole or in part without the prior written authorization from IDENTEC SOLUTIONS.
i-Q350 RCM USER MANUAL Radio Frequency Compliance Statement IDENTEC SOLUTIONS is the responsible party for the compliance of the following devices: MODEL: Region/Country EUROPE: USA: Organization EC FCC Canada: Industry Canada i-Q350 RCM Marking CE OO4-ILR-IQ350WAM OO4-ILR-IQ350WAM2 3538A-IQ350WAM 3538A-IQ350WAM2 The user(s) of these products are cautioned to only use accessories and peripherals approved, in advance, by IDENTEC SOLUTIONS.
i-Q350 RCM USER MANUAL This product contains components that are sensitive to electrostatic discharges. Please observe the special instructions for their protection. Incorrect handling can damage the unit and cause the invalidation of the warranty. Minimum safety precautions against electrostatic discharge: • Establish earth contact before you touch the unit. For example, touch the earthing screw on the unit.
i-Q350 RCM USER MANUAL Contents 1. SAFETY INSTRUCTIONS .............................................................................................. 6 1.1. 1.2. 1.3. 1.4. 1.5. 1.6. 2. INTRODUCTION .......................................................................................................... 9 2.1. 2.2. 3. FUNDAMENTALS.............................................................................................................
i-Q350 RCM USER MANUAL 1. SAFETY INSTRUCTIONS The system described in this manual is for exclusive operation of trained employees. Only qualified personnel that have knowledge of the potential dangers involved should perform the installation, settings, maintenance and repair of the units used. Operational Safety The correct and safe use of these systems assumes that operating and service personnel follow the safety measures described in the manual alongside the generally acceptable safety procedures.
i-Q350 RCM USER MANUAL Spare Parts We recommend that only personnel, original products, spare and replacement parts authorized by IDENTEC SOLUTIONS be used for installation, service and repair. IDENTEC SOLUTIONS does not accept any responsibility for materials used, work carried out or possible consequences from unauthorized third party vendors. Electrostatic Discharge Semi-conductors of the type MOS or CMOS as well as two-pin types and precision resistance are sensitive to ESD.
i-Q350 RCM USER MANUAL 1.3. Responsibility IDENTEC SOLUTIONS reserves the right to make changes and updates to the content contained herein. It is the user’s responsibility to contact the service department for any possible changes or updates to operating and maintenance procedures. 1.4. Updates Updates will be provided upon request. The information in this document may be subjected to changes without prior notice. 1.5.
i-Q350 RCM USER MANUAL 2. INTRODUCTION 2.1. Fundamentals The IDENTEC SOLUTIONS’ SensorSMART Platform is the latest development in asset management, localization and process optimization. Developed to deliver the last mile in industrial communication, the SensorSMART Platform fulfills a niche not previously addressed by available networks.
i-Q350 RCM USER MANUAL 3. INTRODUCTION 3.1. Fundamentals Designed to automate the data collection and business processes associated with refrigerated container management in complex marine and intermodal terminal environments, the Reefer Container Monitoring System (RCMS) from IDENTEC SOLUTIONS represents the next generation in ‘plug and play’ wireless reefer monitoring and control.
i-Q350 RCM USER MANUAL 3.2.2. Polarization of Sensors Vertically Polarized Horizontally Polarized Polarization is dependent on orientation and is rotation symmetrical. VISIBILITY DELIVERED.
i-Q350 RCM USER MANUAL 3.3. System Components—Readers 3.3.1. i-PORT M350-2 The i-PORT M350-2 is a reader for the i-Q350 and i-B350 series of IDENTEC SOLUTIONS’s Response and Broadcast Sensors. Built into a compact housing, the i-PORT M350-2 reads and writes data to the sensors at distances of up to 500 meters (1640 feet) on two antennas.
i-Q350 RCM USER MANUAL Orientation Diagrams: Elliptical polarized antenna Elevation Azimuth For this antenna, the maximum transmit power setting is: • A-9185: -8 dBm 3.4.2. Linear Polarized Antennas Because of the smaller apex angle (60º), this antenna is more suited to selective data collection and restriction of read zones. Depending on the direction of mounting, the antenna’s field is either vertically or horizontally polarized, requiring the sensor to have the same orientation.
i-Q350 RCM USER MANUAL Orientation Diagrams: Linear polarized antenna Elevation Vertical Polarization Azimuth Horizontal Polarization Antenna Orientation For this antenna, the maximum transmit power setting is: • W-900R: VISIBILITY DELIVERED.
i-Q350 RCM USER MANUAL 3.4.3. 1-Wave Rod Antenna Overall Dimensions: 425 × 90 mm Mounting proposal Antenna diagram Vertical For this antenna, the maximum transmit power setting is: • Rod antenna: VISIBILITY DELIVERED.
i-Q350 RCM USER MANUAL 4. TAG MOUNTING SOLUTIONS The Tag can be mounted either with cable straps using the 2 slits at each end, by using screws or a magnet as described in the following 3 subchapters. 4.1. Cable Straps 4.2. Screws VISIBILITY DELIVERED.
i-Q350 RCM USER MANUAL Important Information 1. Only screws with cylindrical heads are suitable for mounting the tag. We do not advise using countersunk screws. If for some reason this should be necessary, then use only with a suitable counter-sunk cushioning disc (refer to UN 1277). 2. The attached bushing is recommended to protect the plastic around the mounting hole from being damaged when tightening the rivet. 3.
i-Q350 RCM USER MANUAL 4.3. Magnet (optional) The tag can be easily removed by grabbing it on the part of its body with the cable outlet. Slightly pull it off the wall and the magnetic holding force is removed at once. DO NOT pull the cable. VISIBILITY DELIVERED.
i-Q350 RCM USER MANUAL 5. CONNECTING TO THE REEFER CONTROLLER Safety Instructions A screened cable must be used for the data cable. Important Note The total cable runs between tag and the monitored device must not exceed a total of 15 m. This is due to limitations of the RS232 (EIA-232) standard. Connecting the i-Q350 RCM to the controller 3 of the 5 connector pins are coded with a small edge to align correctly the plug and connector.
i-Q350 RCM USER MANUAL Step 3 Align the bayonet locking mechanism by rotating the outer ring on the male connector. Step 4 Press both connector together and lock the bayonet mechanism to insure proper electrical connection and weatherproofness. VISIBILITY DELIVERED.
i-Q350 RCM USER MANUAL 6. ACCESSORIES In order to accomodate different installations and to operate with most of the reefer container's plug's variation, we are providing several accessories. 6.1. Extension Cable We are providing a 2 meters (6 ft) extension cable to accomodate installation where the i-Q350 RCM is installed on racks. The extension cable can be used between the i-Q350 RCM and an adaptor. Up to 5 extension cables can be connected together to reach greater distances.
i-Q350 RCM USER MANUAL 6.2. Adaptors Multiple adaptors are available in order to connect the i-Q350 RCM to different type of reefer controllers. Each adaptor is 50 centimeters (19 inches) long and use the standard 5 pin Deustch female connector to connect to the tag. Adaptors can be use in combination with extension cable. Hereafter are the list of adaptors available for the RCMS solution.
i-Q350 RCM USER MANUAL 6.3. Connecting to the tag Follow the process hereafter to connect the extension cable or adaptors to the i-Q350 RCM. Step 1 Align the male connector of the i-Q350 RCM tag to the female connector of the adaptor or extension cable. In order to align correctly the connectors, use the indent and edges highlighted on the pictures on the left. Step 2 Connect the male connector to the female connector.
i-Q350 RCM USER MANUAL Step 4 Press both connector together and lock the bayonet mechanism to insure proper electrical connection and weatherproofness. VISIBILITY DELIVERED.
i-Q350 RCM USER MANUAL 7. TROUBLESHOOTING 7.1. General This chapter covers how faults can be recognized and rectified. There are potentially four main problem sources: • The user control system, including task requirements, communication cables, peripheral units with possible object recognition switches. • The SensorSMART platform including peripheral units and their cables, also potential object recognition switches.
i-Q350 RCM USER MANUAL 8. MAINTENANCE 8.1. General When installed correctly the ILR System will operate virtually maintenance free for many years. However, in the event maintenance is required only trained and authorized personnel are permitted to perform the updates, changes and maintenance necessary. 8.2. Regular Cleaning of The Surface Remove dust with a brush or compressed air. If there are fatty or oily substances use a soft cloth moistened with a mild rinsing agent.
i-Q350 RCM USER MANUAL 9.
i-Q350 RCM USER MANUAL Environmental Conditions Operating Temperature –20 °C to +70 °C (–4 °F to +158 °F) Humidity 10% to 95% relative humidity @ 30°C Shock Multiple drops to concrete from 1m (3ft), 3 times DIN IEC 68-227 3G, 20 sine wave cycles, 5 to 150 Hz, DIN IEC 68-2-6 Vibrations 5G, noise 5 to 1.