User's Manual

i-Q350LX GPS -SAT
USER MANUAL
VISIBILITY DELIVERED. PAGE 25 OF 31
Example
This example shows 3 tags (A, B, C) that are simultaneously triggered by a marker loop (LF marker) and are
configured to burst 3 times. The timeslot (Time between Bursts) is set to the default value of 40 ms.
The last row shows how the random use of the timeslot avoids collision between the tags.
3.3. Impact between measurement, logging and broadcast interval
The intervals for temperature measurement, temperature logging and broadcasts can be configured
independently.
Example 1
Measurement Interval: 5 sec
Broadcast Interval: 20 sec
Logging Interval: 60 sec