In this mode, the Transponder will broadcast its distance measured, only after the 6 ranging intervals
are done. In order to save the amount of data transmitted, the Transponder will send only the
smallest distance measured with each reader or i-SAT. As soon as the Transponder considers it has
stopped moving, it resumes its standard behavior.
Ranging Interval: This sets the standard ranging interval, which the Transponder performs
constantly. This can be set in steps of seconds from 1 second up to 4 hours 39 minutes. The
default value is 5 minutes.
Alternate Ranging Interval: This sets the faster ranging interval, triggered by the motion
sensor. This can be set in steps of seconds from 1 second up to 4 hours 39 minutes. The default
value is 10 seconds.
Classic Use Cases
Case
Ranging interval
Alternate
ranging
interval
In motion
behavior
Localization on fix interval
only
Application dependent
0
0 (on stop)
Localization on fix interval
and different interval when
moving
Application dependent
Application
dependent
1 (continuous)
Localization on fix interval
and fast positioning when
stopping
Application dependent
Application
dependent
0 (on stop)
Localization only when
moving
0
Application
dependent
1 (continuous)
Localization only when
stopping
0
Application
dependent
0 (on stop)
Do not perform localization
0
0
0 (on stop)
4.7. Motion Sensor Settings
Note: These settings can be found in the ILR Tag Configuration software tool in the edit block
“Motion Sensor”
Stop Movement Counter:
Maximum value of the motion counter. If this value is reached, the
counter stops increasing. Range: 0 to 65534 (default: 150)
Movement On
: Threshold at which the Transponder is considered to be in motion. Typically, this
is the upper value. Range: 0 to 65534 (default: 100)
Movement Off:
Threshold at which the Transponder is considered to remain in its place. Typically,
this is the lower value. Range: 0 to 65534 (default: 40)
Increment by
: Rate of increase of the movement counter. Range: 1 to 254 (default: 1)
Decrement by
: Rate of decrease of the movement counter. Range: 1 to 254 (default: 1)