User's Manual

i-PORT MB – Manual
Version 1.1 02.02.2007 Page 23/
37
TelegramCount 0/1 This byte is only transmitted if the
SubCmd is 0x01. It is incremented
each time it is transmitted. If the value
on host and reader are inconsistent the
complete list of tags can be scheduled
for retransmission with parameter
0x15. If you should see errors here
please also check for timeouts and crc
errors on the host and on the reader
(parameter 0x04)
crc16 2
End Delimiter EOT 1
Note 1: Time in seconds, signed integer (relative to the time the last command was issued).
TimeFirst:This is the first time the tag has been detected on one of the antenna
TimeLast: This is the last time the tag has been detected on one of the antenna
RSSI: This is the maximum value of the last detection information on both antennas
MAX(RSSI ant 1, RSSI ant2) for last detection time.
RSSI Max this is the maximum RSSI value detected on any antenna. MAX (Max RSSI ant1, Max
RSSI ant2) since last transmission.
#seen: This is the maximum number of detection of the tag on both antenna MAX(#seen
ant1, #seen ant2) since last transmission.