User's Manual
i-MARKInstallation and Hardware Manual
Page 22 of 22
7 Technical Specifications
7.1 Operating Data
Range i-MARK 2: Adjustable by the loop current up to app 3 m
i-MARK 3: Depending on loop design and adjustable by the loop current
Operating Frequency 125 kHz
Number of loops 1
RF error protection 16 bit CRC
Certification CE, EN 300220 (EU), FCC Part 15 (US)
Firmware updates Via host computer interface
Configuration memory Non-volatile EEPROM memory
Status display 4 LEDs
Maximum number of
readers per daisy chain
16
Maximum cable runs
between two i-MARKS
300 m
Maximum overall cable
runs of daisy chain
1000 m (only with GND free power supplies at every i-MARK)
7.2 Electrical Data
Host interface RS422, Daisy Chain
Baud rate 115 kBaud, fixed
Supply voltage i-MARK 2: 10 to 30 V DC or 230 VAC (internal PSU, Europe only)
i-MARK 3: 10 to 20 V DC
Power consumption Max. 20 W per i-MARK
7.3 Mechanical Data
Overall dimensions i-MARK 2: 285 × 202 × 56.25 mm
i-MARK 3: 170 × 94 × 67 mm
Case material Plastics
7.4 Environmental Conditions
Operating temperature –20
°C to +60
°C
Humidity Up to 90% non-condensing
Protection class IP40, IP65 with additional protection for connector, Ref. IEC 529