User's Manual
i-B2 S – User’s Guide
Version 1.0 03.08.2006 Page 7/12
Appendix A: Technical Specifications
Performance
Read range to i-PORT R2 Up to 100 m (300 ft) (free air)
Read range to i-CARD R2 Up to 100 m (300 ft) (free air)
Operating frequency 868 MHz (EC) or 915 MHz (NA)
Operation Transmits in regular intervals a pre-programmed data string
Repetition rate (ping rate) 0.5 – 60 seconds in 0.5 second steps
Transmit power <1 mW
Certification CE (EN 300 220-1, -3; ETSI EN 301 489-1, -3),
FCC part 15 (US), Industry Canada
pending
Electrical
Power source Lithium battery (not replaceable)
Expected battery life See table
Data
Programmability One time
Programming and activation Wireless by proximity device over a distance of maximum 5 cm
Reprogrammable Yes
Deactivation Yes
Lockable Yes
Memory capacity 4 bytes ID + 9 bytes user data
Environmental
Operating temperature -30°C to +70°C (-22ºF to +158ºF)
*1
-50°C to +85°C (-58°F to +185°F)
*1
Shock 50 G, 3 times DIN IEC 68-2-27
Multiple drops to concrete from 1 m (3 ft)
Vibration 3 G, 20 sine wave cycles, 5 Hz to 150 Hz,
DIN IEC 68-2-6
5 G, noise 5 Hz to 1000 Hz, 30 minutes
DIN IEC 68-2-64
Physical
Dimensions 131 mm x 28 mm x 21 mm (5.2 in. x 1.1 in. x 0.85 in.)
Case Material Plastic (Luran
®
S)
Mass 50 grams (1.75 ounces)
Enclosure rating IP 65 — Protected against dust and low-pressure jets of water
Colour dark blue
*1: Depending on battery type