User's Manual

MorphoAccess® SIGMA Extreme Series - Installation Guide
Identity & Security
Section 2 :General Description
26
This document and the information therein are the property of Safran Identity & Security.
They must not be copied or communicated to a third party without the prior written authorization of Safran
2017_2000024418 - Draft
V0
January 2017
Output relay switches
Access granted: 1 switch two outputs (normally “open” and normally
“closed”)
30V 1A max (Resistive loads)
USB host port
External port for terminal configuration through a USB mass storage
key
Internal port to connect an external Wi-Fi™ USB dongle using an
adapter cable
Input signals
LED1/LED2 to activate the access granted relay
Power supply
12 to 24 V DC power supply (1A min @12V)
Or by Power Over Ethernet through RJ-45 connector
Note for UL 294 Compliance power supply shall be UL 294 and UL
294B with power limited output
Security of the terminal
Anti-tamper-pulling switches
Tamper-pulling detection: one switch closed when product wall
mounted, open when pulled out
Size and weight
W x H x D: 130mm x 300mm x 95mm
(5,12” x 11,82” x 3,74”)
Weight : ~1,5kg
Environmental conditions
Operating temperature -20 °C to + 60 °C (-4°F to 140°F)
Operating humidity 10 % < RH < 95 % (non condensing)
Storage temperature -25 °C to + 70 °C (-13°F to 158°F)
Storage humidity 5% < RH < 95 %
IP65 rated
For UL 294 compliance, the products are rated for indoor use. IP65
was not verified by UL
The terminal should be installed in controlled lighting conditions
Avoid direct exposure to sunlight or to UV lights
Certification planned
CE, IEC 60950-1, FCC Part 15, RSS210 - Issue 8 : 2010, RSS-102 - Issue
5 : 2015, RSS-Gen Issue : 2014, RoHS, REACh, WEEE