User's Manual

MorphoAccess® SIGMA Lite Series Installation Guide
Section 7 : Recommendations
2015_2000007248-V1 - Draft
This document and the information therein are the property of Morpho. They must not be
copied or communicated to a third party without the prior written authorization of Morpho
June 2015
Ethernet communication
4G Lite Series
MA-J Series
MA SIGMA Lite Series
RJ45 connector or wires
Block connector
RJ45 connector
RJ45 connector or wires
Serial communications
4G Lite Series
MA-J Series
MA SIGMA Lite Series
Wiegand
Yes
Output ports
Input ports
No LED IN/OUT port
Interfaces
multiplexed on the
same lines.
Wiegand, Dataclock
and RS-485 (Half
duplex) protocols
shall only be
enabled at one time,
else priority is given
to Wiegand, then
Dataclock, then
RS485.
Wiegand :
Output port
only + LED
IN inputs
Dataclock:
Output port
Yes
Output port
Input ports
LED OUT port
LED IN by GPO
Dataclock
No
Yes
RS-485
Half duplex
(Slave only)
Half duplex
(Slave only)
GPI/GPO
4G Lite Series
MA-J Series
MA SIGMA Lite
Series
GPI
2 GPI
No
2 GPI
GPO
1 GPO
(1 TTLOUT_H and 1
TTLOUT_L)
No
2GPO
(≈ 2 TTLOUT_H only)
GPO current
limitation
5mA@5V for 4G
-
5mA@5V