Installation
Required tools (not supplied)
Two (2) raw plugs + Two (2) ø 4mm max and length 30mm screws.
One (1) screwdriver adapted to screws above.
One (1) Drill (with a drill bit diameter adapted to raw plugs above).
One (1) hole saw (depending on installation case).
A (1) Torx T10 screwdriver
Deadbolt/door strike
Snubber diode required to protect regulated DC power supply from inductive
kickback (1N4007 diode or equivalent recommended)
Separate power supply for the deadbolt/door strike based on supplier's
recommendations.
External relay (if required)
Networking cable
For UL-294 compliance, an earthed screen in the wire or around all wires to/from
product is only required when the wires share space/compartment/tube with high
voltage cables.
Equipment from the initial package to use
One (1) Terminal’s body,
One (1) pre-wired back door,
One (1) wall plate,
One (1) Protection accessory (optional) to insert over the biometric sensor