Example 1: send alarm message in Wiegand, and output local alarm signal
In case of anti-tamper or anti-pulling detection, the terminal must:
• Send an alarm message to a distant system, using Wiegand protocol. The identifier
(error code) of the alarm message is 62221.
• Emit a local alarm signal.
Send an alarm message in UDP quietly in case of intrusion detection
app/tamper alarm/level = 2 Anti-pulling or anti-tamper: the
terminal output a local alarm signal and
send an alarm message to a distant
system
app/failure ID/alarm ID = 62221 The identifier of alarm message is
62221.
app/failure ID/enabled = 1 Error and alarm messages are allowed
while using Wiegand or DataClock
protocols.
app/send ID wiegand/enabled = 1 Enables to send message though serial
channel using Wiegand protocol.
Example 2: send an alarm message in UDP (no local alarm signal).
In case of anti-tamper or anti-pulling detection, the terminal should send an alarm
message to a distant system, through Ethernet (or Wi-Fi™), using UDP protocol. No
local alarm signal is required.
Send an alarm message in UDP in case of anti-pulling or anti-tamper detection
app/tamper alarm/level = 1 Anti-tamper or anti-pulling : send an
alarm message to a distant system only
(no alarm signal emitted by the
terminal)
app/send ID UDP/enabled =1 Enables message sending though
Ethernet (or Wi-Fi™) channel using
UDP protocol.