Access control result
Information for the user
The MorphoAccess® terminal communicates the result to the user, by a local audible
and visible signal. These signals are described in the Section 11 Man Machine
Interface section.
For example:
When the access is granted, the terminal emits a green flash and a high pitched
note
When the access is denied, the terminal emits a red flash and a low pitched note
Information for the administrator
The MorphoAccess® terminal creates a record for each access request, in a internal
log file, Each record contains the date and the time, the user’s identifier (if available),
and the result of the local access control check.
This feature is described in the Access request result log file section.
Integration in an access control system
At the end of the access rights control, the MorphoAccess® terminal is able to:
Send a message, with data related to the access request, to a distant system which
could be a simple storing system, or a Central Security Controller. This feature is
described in the Sending the access control result to a distant system section.
Wait for the answer of a distant system answer before emitting the result signal for
the user. This feature is described in the LED IN feature section.
Activate an internal relay (if the access is granted to the user), as described in
Internal Relay activation on Access Granted result section.
The format of the messages (which include the user’s identifier) send to the distant
system is described in the MorphoAccess® Remote Messages Specification document.