User's Manual

MorphoAccess® VP Series - User Guide
Section 3: Connecting a MorphoAccess® to a PC
35 M
ORPHO DOCUMENT
.
R
EPRODUCTION AND
D
ISCLOSURE
P
ROHIBITED
SSE-0000082427-01
January 2011
Wi-Fi™ Network configuration
Requirements
Wi-Fi™ connection is available under the following mandatory conditions:
a Morpho Wi-Fi™ USB adapter must be plugged in the front USB port of the
terminal (the bottom cover must be removed to give access to this port). The
installation procedure is described in the MorphoAccess® VP Series Installation
Guide,
a MorphoAccess® Wi-Fi™ license must be present in the terminal (as described
in Terminal license management section),
the terminal must be disconnected from any wired network (it means no Ethernet
cable plugged) : Wi-Fi™ connection and Ethernet cable connection are mutually
exclusive,
After Wi-Fi™ license downloading and Wi-Fi™ USB adapter installation, make sure
to reboot the terminal by pressing the reset button (see paragraph Power supply
interface for more information on reset button).
NOTE: Both Wi-Fi™ USB adapter and license can be ordered under the reference
"MA WI-FI PACK".
Configuration
The Wi-Fi™ network configuration is described in the chapter 15 of the
MorphoAccess® Enrolment station User Guide document.
Wi-Fi™ troubleshooting
If the terminal is configured to use the Wi-Fi™ connection with the Wi-Fi™ USB
adapter plugged in and if there is no license present, the MorphoAccess® VP Series
terminal will display a 1-second red flash and will emit a short-low tone.
To solve this issue, unplug the Wi-Fi™ USB adapter and restart the terminal.
To restart the terminal use the reset button located in front face of the terminal (see
Power supply interface section for more information on reset button).
The Wi-Fi™ configuration parameters are described in the MorphoAccess®