Section 11:
Compatibility with an Access Control System
SSE-0000082427-01 M
ORPHO DOCUMENT
.
R
EPRODUCTION AND
D
ISCLOSURE
P
ROHIBITED
102
January 2011
Then to reduce the user wait time, the value of the wait time for GND1/GND2 signal
must be defined to value a little bit greater than maximum controller answer delay.
Using LED1 and LED2 signals
When the controller provides a relay contact for each possible answer, then:
The “access denied" relay contact must be connected to LED1 and GND wires
The “access granted” relay contact must be connected to LED2 and GND wires.
Activation key
This feature is activated by a dedicated configuration key.
LED IN feature activation
app/led IN/enabled = 0 Disabled (default)
app/led IN/enabled =1 Enabled
Configuration key
The value of the wait time for the answer of distant system (LED1 or LED2 signal) is
defined by a dedicated configuration key. In case of timeout, the access is denied.
LED IN acknowledgement timeout in 10 ms
app/led IN/controller ack timeout 300 (0 to 268435455)