SWITCHING ON
1. Switch the device on using the ON/AUTO/OFF switch.
ON/AUTO/OFF
switch
Light modes
ON
OFF
AUTO
Light on
Light off
Sensor on
WALKING TEST
Test the detection area and the movement sensor by conducting a
walking test in which you walk into the detection area of the sensor
from outside of its range.
CLEANING AND CARE
• Always switch off the device before cleaning.
• Remove dust with a soft dust cloth.
• Do not use any wet sponges, wax, spray polish or abrasive agents.
• Caution: Water must not penetrate the inside of the housing. If this
does happen, let it dry out thoroughly before putting it into operation
again.
TECHNICAL DATA
Battery operation: 4 x AA, 6 V
Light source: 6 x LEDs
Maximum detection distance: 5m (at an ambient temperature
of 22°C)
Detection angle: 110°
Operation temperature and
ambient temperature:
-10°C – 40°C
LX-LD-P300_A6_120829.indb 16 30/8/12 4:16 PM