Operation Manual

16
SWITCHING ON
1. Switch the device on using the ON/AUTO/OFF switch.
ON/AUTO/OFF
switch
Light modes
ON
OFF
AUTO
Light on
Light off
Sensor on
WALKING TEST
Test the detection area and the movement sensor by conducting a
walking test in which you walk into the detection area of the sensor
from outside of its range.
CLEANING AND CARE
Always switch off the device before cleaning.
Remove dust with a soft dust cloth.
Do not use any wet sponges, wax, spray polish or abrasive agents.
Caution: Water must not penetrate the inside of the housing. If this
does happen, let it dry out thoroughly before putting it into operation
again.
TECHNICAL DATA
Battery operation: 4 x AA, 6 V
Light source: 6 x LEDs
Maximum detection distance: 5m (at an ambient temperature
of 22°C)
Detection angle: 110°
Operation temperature and
ambient temperature:
-10°C – 40°C
LX-LD-P300_A6_120829.indb 16 30/8/12 4:16 PM