Marking
For YW series pilot lights and illuminated pushbuttons, legends and
symbols can be engraved on built-in marking plates, or printed mylar
film can be inserted under the lens for labeling purposes. Mylar film is
not supplied with the YW series and must be supplied by the end user.
Built-in Marking Plate and Marking Film Size
Unit Pilot Light Illuminated Pushbutton
Built-in Marking Plate
Engraving depth: 0.5 mm maximum
Marking plate material: White acrylic
Applicable Marking Film
0.1-mm-thick × 2 sheets or 0.2-mm-thick × 1 sheet
Film material: Mylar (recommended)
Note: Marking lm is not supplied with the pilot light or illuminated pushbutton.
Replacement (LED and incandescent lamps)
Lamps can be replaced using the lamp holder tool (OR-55) from the
front of the panel, or by removing the contact block from the operator
unit.
Removing the Lamp from the Front of the Panel
To remove, gently insert the lamp holder tool onto the lamp head. Then
push slightly, and turn the lamp holder tool to the left.
Installing the Lamp from the Front of the Panel
1. To install, insert the lamp head into the lamp holder tool, and hold
the lamp as shown in the figure below.
Lamp Lamp Removal Tool
2. Place the pins on the lamp base to the grooves in the lamp socket.
Insert the lamp and turn it to the right.
Pilot Light Illuminated Pushbutton
Note: LED lamps in unibody pilot lights cannot be replaced.
Removing Contact Blocks
and Full Voltage Adapters
Insert a flat screwdriver between the
latch and contact block mounting
adapter, and disengage the latch.
Make sure to remove the lamp and
contact blocks before removing the
full voltage adapter.
Lamp
1
3
22
Full Voltage Adapter
Contact Block
Tightening Torque for Terminal Screws
Tighten terminal screws to a torque of 1.0 N·m.
Anti-rotation Ring and Mounting Panel
Turn the TOP marking on the operator and the mark on the anti-
rotation ring to the recess on the mounting panel.
Projections (p mark)
Anti-rotation Ring
Locking Ring
Panel Thickness 1.2 to 4.5 mm
Mounting Panel Thickness
The mounting panel must be 0.8 to 6.0 mm in thickness. When
optional accessories are added, the applicable panel thickness changes
as shown below.
P
anel Thickness
0.8 to 6 mm
Panel Thickness
0.8 to 3.2 mm
Padlock Cover
HW9Z-KL1P
Contact Bounce
When pressing or turning the operator, the NC and NO contacts will
bounce. When designing a control circuit, take the contact bounce time
into consideration (reference value: 20 ms).
ø21.0
1.0
Engraving Area
ø15.2
1.2
Engraving
Area
ø22.7
20.8
-0.2
0
-0.2
0
-0.2
0
ø17.2
-0.2
0
15.0