ø30 XN Series Emergency Stop Switches
Operating Instructions
Removing the Contact Block
 Grab
 Grab
Latch
Bayonet Ring (yellow)
 Pull
 Turn counterclockwise
First unlock the operator button. 
Grab the yellow bayonet ring 
➀
 and 
pull back the bayonet ring until the 
latch pin clicks 
➁
, then turn the con-
tact block counter clockwise and pull 
out 
➂
. 
Notes for removing the contact block
1. Do not attempt to remove the contact block while the oper ator is
latched, otherwise the switch may be damaged.
2. When the contact block is removed, the monitor contact (NO contact)
is closed.
3. While removing the contact block, do not use excessive force, other-
wise the switch may be damaged.
4. An LED lamp is built into the contact block for illuminated push-
buttons. When removing the contact block, pull the contact block
straight to prevent damage to the LED lamp. If excessive force is
used, the LED lamp may be damaged and fail to light.
Panel Mounting
Rubber Gasket
Operator without
thread
TOP Marking
Anti-rotation
Projection
Locking Ring
Remove the locking ring from 
the operator and check that the rub-
ber gasket is in place. Insert the 
operator from panel front into the 
panel hole. Face the side without 
thread on the operator with TOP 
marking upward, and tighten the 
lock ing ring using ring wrench 
XN9Z-T1 or TWST-T1 to a torque of 
2.5 N·m maximum.
When using a nameplate
When using a nameplate HNAV-, 
break the projection from the nameplate using pliers.
Installing the Contact Block
V Marking
W
 Marking
 Push
TOP Marking
 Turn clockwise
First unlock the operator button. 
Align the small ▼ marking on the 
edge of the operator with the small ▲ 
marking on the yellow bayonet ring. 
Hold the contact block, not the bayo-
net ring. Press the contact block onto 
the operator and turn the contact 
block clockwise until the bayo net ring 
clicks.
Notes for installing the contact block
1. Do not attempt to install the contact block when the opera tor is
latched, otherwise the switch may be damaged.
2. Make sure that the bayonet ring is in the locked position.
Installing & Removing Terminal Covers
XW9Z-VL2M
➀ Place the projections
on the contact block.
TOP Markings
➁ Press the
terminal cover
Projections
Slots
To install the terminal cover, align 
the TOP marking on the terminal 
cover with the TOP marking on 
the contact block. Place the two 
projec tions on the bottom side of 
the contact block into the slots 
in the terminal cover. Press the 
terminal cover toward the contact 
block.
To remove the terminal cover, 
(Pull)
TOP Marking
TOP Marking
Projections
pull out the two latches on the top 
side of the terminal cover. Do not 
exert excessive force to the latches, 
otherwise the latches may break.
IP20 Fingersafe Terminal Cover 
XW9Z-VL2MF
(Press)
TOP Marking
TOP Marking
To install the IP20 fingersafe terminal 
cover, align the TOP marking on the 
cover with the TOP marking on the 
contact block, and press the cover 
toward the contact block.
Notes:
1. Once installed, the XW9Z-VL2MF cannot 
be removed.
2.  With the XW9Z-VL2MF installed, crimping terminals cannot be used. Use solid 
wires.
3.  The XW9Z-VL2MF cannot be installed after wiring.
4. Make sure that the XW9Z-VL2MF is securely installed. IP20 cannot be 
achieved when installed loosely, and electric shocks may occur.
Notes for Operation
When using the XN emergency stop switches in safety-related part 
of a control system, observe safety standards and regulations of the 
relevant country or region. Also be sure to perform a risk assessment 
before operation.
Wiring
Tighten the M3 terminal screws to a torque of 0.6 to 1.0 N·m.
Contact Bounce
When the button is reset by pulling or turning, the NC main contacts 
will bounce. When pressing the button, the NO monitor contacts will 
bounce. 
When designing a control circuit, take the contact bounce time into 
consideration (reference value: 20 ms).
LED Illuminated Switches
An LED lamp is built into the contact block and cannot be replaced.
Handling
Do not expose the switch to excessive shocks and vibra tions, for 
example by operating the switch with tools. Other wise the switch may 
be deformed or damaged, causing malfunction or operation failure.
Projection