The World’s First ø16 mm, 4-contact Emergency Stop Switch.
Compact size - only 27.9 mm deep behind the panel.
Lead-free, RoHS compliant.
The depth behind the panel is only 27.9 mm for 1 to 4 con-
tacts.
IDEC’s original “Safe break action” ensures that the con-
tacts open when the contact block is detached from the
operator.
1 to 4NC main contacts and 1NO monitor contact
Push-to-lock, Pull or Turn-to-reset operator
Direct opening action mechanism (IEC60947-5-5, 5.2,
IEC60947-5-1, Annex K)
Safety lock mechanism (IEC60947-5-5, 6.2)
Degree of protection IP65 (IEC60529)
Two operator sizes: ø29 and ø40 mm
Dark red (Munsell 5R4/12) or bright red (Munsell 7.5R4.5/
14) colors are available for the operator of emergency stop
switches, and gray for stop switch operators.
UL, c-UL approved. EN compliant
Direct Opening Action
Note: Except for stop switches (operator color: gray).
Contact Ratings
(NC main contacts/NO monitor contact)
Minimum applicable load: 5V AC/DC, 1 mA (reference value)
(Operating area may vary according to the operating conditions and load
types.)
The rated operating currents are measured at resistive/inductive load types
specied in JIS C8201-5-1.
Specifications
Note: Except for stop switches (operator color: gray).
Standard Mark
Approval Organization/
File No.
UL508
CSA C22.2 No. 14
UL/c-UL File No. E68961
EN60947-5-1
EN60947-5-5 (Note)
TÜV Product Service
Self-declaration (European
Commission’s Low Voltage
Directive)
Rated Insulation Voltage (Ui) 300V
Rated Current (Ith) 5A
Rated Operating Voltage (Ue) 30V 125V 250V
Rated Operating Current
Main
Contacts
AC 50/60 Hz
Resistive Load
(AC-12)
–3A3A
Inductive Load
(AC-15)
1.5A 1.5A
DC
Resistive Load
(DC-12)
2A 0.4A 0.2A
Inductive Load
(DC-13)
1A 0.22A 0.1A
Monitor
Contacts
AC 50/60 Hz
Resistive Load
(AC-12)
1.2A 0.6A
Inductive Load
(AC-14)
0.6A 0.3A
DC
Resistive Load
(DC-12)
2A 0.4A 0.2A
Inductive Load
(DC-13)
1A 0.22A 0.1A
Applicable Standards
IEC60947-5-1, EN60947-5-1
IEC60947-5-5 (Note), EN60947-5-5 (Note)
JIS C8201-5-1, UL508, CSA C22.2 No. 14
Operating Temperature –25 to +60°C (no freezing)
Operating Humidity 45 to 85% RH (no condensation)
Storage Temperature –45 to +80°C
Operating Force
Push to lock: 10.5N
Pull to reset: 10N
Tu rn to reset: 0.16 N·m
Minimum Force
Required for Direct
Opening Action
60N
Minimum Operator
Stroke Required for
Direct Opening Action
4.0 mm
Maximum Operator
Stroke
4.5 mm
Contact Resistance 50 m maximum (initial value)
Insulation Resistance 100 M minimum (500V DC megger)
Overvoltage Category II
Impulse Withstand
Voltage
2.5 kV
Pollution Degree 3
Operation Frequency 900 operations/hour
Shock Resistance
Operating extremes: 150 m/s
2
Damage limits: 1000 m/s
2
Vibration Resistance
Operating extremes: 10 to 500 Hz, amplitude 0.35 mm
acceleration 50 m/s
2
Damage limits: 10 to 500 Hz, amplitude 0.35 mm
acceleration 50 m/s
2
Mechanical Life 250,000 operations minimum
Electrical Life
100,000 operations minimum
250,000 operations minimum (24V AC/DC, 100 mA)
Degree of Protection IP65 (IEC60529)
Short-circuit Protection 250V/10A fuse (Type aM, IEC60269-1/IEC60269-2)
Conditional
Short-circuit Current
1000A
Te rminal Style Solder terminal, PC Board terminal
Recommended
Tightening Torque
for Locking Ring
0.88 N·m
Connectable Cable 1.25 mm
2
maximum (AWG16 maximum)
Soldering Conditions
20W/5 seconds maximum, or 260°C/3 seconds
maximum
Weight ø29 mm type: 23 g, ø40 mm type: 28 g
ø16mm XA Series Emergency Stop Switches