Datasheet
www.apem-idec.eu
D-035
APEM
Switches & 
Pilot Lights
Control Boxes
Emergency 
Stop Switches
Enabling 
Switches
Safety Products
Explosion Proof
Terminal Blocks
Relays & Sockets
Circuit 
Protectors
Power Supplies
LED Illumination
Controllers
Operator 
Interfaces
Sensors
AUTO-ID
Emergency Stop Switches
X6
XA
XW
XN
SEMI
ø22 XW Series Emergency Stop Switches
• Turn off power to the XW series emergency stop switch before start-
ing installation, removal, wiring, maintenance, and inspection of the 
relays. Failure to turn power off may cause electrical shock or re 
hazard.
• For wiring, use wires of the proper size to meet the voltage and 
cur rent requirements. Tighten the M3 terminal screw to a tightening 
torque of 0.6 to 1.0 N·m. Failure to tighten the terminal screws may 
cause overheating and re.
Removing the Contact Block
First unlock the operator button. Grab the bayonet ring   and pull back 
the bayonet ring until the latch pin clicks 
, then turn the contact block 
counterclockwise and pull out 
.
Turn counterclockwise
Bayonet Ring
Grab
Grab
Pull
Notes for removing the contact block
1.  When the contact block is removed, the monitor contact (NO contact) 
is closed.
2.  While removing the contact block, do not exert excessive force, oth-
erwise the switch may be damaged.
3.  An LED lamp is built into the contact block for illuminated push-
buttons. When removing the contact block, pull the contact block 
straight to prevent damage to the LED 
lamp. If excessive force is exerted, the LED lamp may be dam aged 
and fail to light.
Panel Mounting
Remove the locking ring from the operator. Insert the operator from 
panel front into the panel hole. Face the side without thread on the 
operator with TOP marking upward, and tighten the locking ring using 
ring wrench MW9Z-T1 to a torque of 2.0 N·m maximum.
Operator without thread
TOP marking
Rubber Gasket
Locking Ring
Installing the Contact Block
First unlock the operator button. Align the small   marking on the edge 
of the operator with the small 
 marking on the yellow bayonet ring. 
Hold the contact block, not the bayonet ring. Press the contact block 
onto the operator and turn the contact block clockwise until the bayonet 
ring clicks.
marking
marking
Push
Turn clockwise
Notes for installing the contact block
Make sure that the bayonet ring is in the locked position. Check that the 
two projections on the bayonet ring are securely in place.
Wiring
Solder Terminal
1.  The applicable wire size is 1.25 mm
2
 maximum.
2.  Solder the terminal at a temperature of 310 to 350°C within 3 sec-
onds using a soldering iron. Sn-Ag-Cu type is recommended when 
using lead-free solder. When solder ing, do not touch the enabling 
switch with the soldering iron. Also ensure that no tensile force is 
applied to the ter minal. Do not bend the terminal or apply excessive 
force to the terminal.
3.  Use a non-corrosive rosin flux.
4.  Because the terminal spacing is narrow, use protective tubes or 
heat shrinkable tubes to avoid burning of wire coating or short cir-
cuit.
PC Board Terminal
1.  When mounting a contact block on a PC board, provide sufficient 
rotating space for the PC board when installing and removing the 
contact block.
2.  When mounting an XW emergency stop switch on a PC board, make 
sure that the operator is securely installed.
3. Do not solder by flow soldering. Otherwise, damage may be caused. 
 Safety Precautions
Instructions
Projections
Unlatched
Latched