Datasheet
www.apem-idec.eu  www.apem-idec.eu
D-003 D-004
Emergency Stop Switches Selection Guide
Direct Opening Action 
All normally closed contact elements of an emergency stop 
devices shall have a direct opening action (positive opening 
action), according to annex K of IEC 60947-5-1. 
(IEC 60947-5-5; 5.2)
Safety Lock Mechanism 
The emergency stop signal shall be maintained until the 
emergency stop device is reset (disengaged). 
(IEC 60947-5-5; 6.2)
Operator Stroke
High
Low
E
n
e
r
g
y
Normal Latched Normal Latched
3rd Generation
(Reverse Energy Structure)
2nd Generation
(Conventional)
Operator Stroke
High
Low
E
n
e
r
g
y
Main contacts
(NC): ON
(machine can
operate)
Main contacts
(NC): ON
(machine can
operate)
Normal Latched Normal Latched
Main contacts (NC):
ON (machine can
operate)
Main contacts (NC): OFF
(machine cannot operate)
Main contacts 
(NC): OFF
(machine 
cannot operate)
Main contacts 
(NC): OFF
(machine 
cannot operate)
Main contacts (NC) 
are always inclined 
to turn on (danger).
Main contacts (NC) 
are always inclined 
to turn off (safe).
Safe Break Action
When the contact block is detached from the operator, the NC 
contact opens (OFF).
When the contact block is detached from the operator, the 
cam directly opens the NC main contacts (contacts are off). 
(Patented)
12
34
Operator
Contact Block
Closed ON
Open OFF
Pull Reset Turn Reset
Reverse Energy Structure
With X series emergency stop switches, the potential energy 
level of the latched status is lower than that of normal status. 
In the event the switch is damaged due to excessive shocks, 
the NC contacts will turn off, thus stopping the machine 
(patented design).
Complies to international safety standards
Third Generation Emergency Stop Switches
Resetting
X series can be reset easily either by pulling or turning. 
Safet and easy-to-use.
IDEC’s Unique Safety Technology  ———————————————————————————————
International Safety Standards  ———————————————————————————————
UL508, CSAC22.2No.14, IEC60947-5-5, UL991, NFPA79, EN60947-5-1, EN60947-5-5, GB14048.5