Manual

Instruction Manual SG4-B Series
7
NOTE
: K value is:
2000 mm/s if the calculated value of S is 500 mm
1600 mm/s if the calculated value of S is > 500 mm
When devices with > 40 mm resolution are used, the height of the top
beam has to be 900 mm (H2) from machine supporting base while
the height of the bottom beam has to be 300 mm (H1).
If the safety light curtain must be mounted in a horizontal position
(Fig.4), the distance between the dangerous area and the most
distant optical beam must be equal to the value calculated using the
following formula:
S = 1600 mm/s (t
1
+ t
2
) + 1200 – 0.4 H
where:
S = Minimum safety distance in mm.
t
1
= Response time of the ESPE in seconds
(see section 10 “Technical data”)
t
2
= Machine stopping time in seconds.
H = Beam height from ground. This height must always be less than
1,000 mm.
Fig. 4