Datasheet

PS6R Switching Power Supplies
Specifications
PS6R
Part No. PS6R-F24 (120W) PS6R-G24 (240W) PS6R-J24 (480W)
Input
Input Voltage (Note 1) (Note 2)
100 to 240V AC
(Voltage range: 85 to 264V AC/110 to 350V DC)
Frequency 50/60 Hz
Input Current
(Typical)
100V AC 1.4A 2.7A 5.5A
230V AC 0.7A 1.2A 2.3A
Inrush
Current
100V AC
9A max. (Ta=25C, at cold start)
230V AC
20A max. (Ta
=
25C, at cold start)
Leakage
Current
120V AC 0.5mA max.
230V AC 1mA max.
Efficiency
(Typical) (Note 3)
100V AC 90% 90% 91%
230V AC 90% 91% 93%
Power Factor
(Typical)
100V AC 0.99 0.99 0.98
230V AC 0.96 0.97 0.97
Output
Rated Voltage/Current 24V/5A 24V/10A 24V/20A
Adjustable Voltage Range ±10%
Output Holding Time 20ms min. (at rated input and output)
Start Time (Note 4)
800ms max. (at rated input and output)
Rise Time
200ms max. (at rated input and output)
Regulation
Total Fluctuation ±5% max.
Input Fluctuation 0.4% max.
Load Fluctuation 0.6% max.
Temperature Change 0.05%/C max. (–10 to +60C)
Ripple (including noise)
1% p-p max. (0 to +60C)
1.5% p-p max. (–10 to 0C)
Supplementary
Functions
Overcurrent Protection
105 to 120% (auto reset)
(output current when voltage drops by 5%)
Overvoltage Protection
Output off at 120% (Note 5)
Operation Indicator
LED (green)
Voltage Low
Indication
LED (amber)
Dielectric Strength
Between input and output
terminals
3000V AC, 1 minute
Between input and
ground terminals
2000V AC, 1 minute
Between output and
ground terminals
500V AC, 1 minute
Insulation Resistance
100M min. 500V DC megger (between input and output terminals/between input and ground terminals)
(at room temperature and normal humidity)
Operating Temperature –10 to +70C (no freezing) (Note 2)
Operating Humidity 20 to 90% RH (no condensation)
Storage Temperature –25 to +75C (no freezing)
Storage Humidity 20 to 90% RH (no condensation)
Vibration Resistance
10 to 55 Hz, amplitude 0.375 mm (using one BNL6 each on the right and left of the PS6R)
2 hours each in 3 axes, 6 directions
Shock Resistance
300 m/s
2
(150 m/s
2
when using a PS9Z-6R1F panel mounting bracket), 3 times each in 6 directions
(using one BNL6 each on the right and left of the PS6R)
EMC
EMI EN61204-3 (Class B)
EMS EN61204-3 (industrial)
Safety Standards UL508 (UL listed), CSA C22.2 No. 107.1 (c-UL listed), IEC/EN60950-1, EN50178
Degree of Protection IP20 (IEC 60529)
Dimensions (mm) 125 H × 37 W × 125 D 125 H × 60 W × 125 D 125 H × 85 W × 125 D
Weight (approx.) 630g 960g 1400g
Terminal Screw M3.5
Note 1: Input voltage approved by safety standards is 100 to 240V AC. DC input is not approved by safety standards.
Note 2: For output derating curves and operating temperature approved by safety standards, see page 7.
Note 3: Under stable state.
Note 4: At light load, electric charge may remain inside the power supply after the power has turned off. Turn on the power after sufficient interval.
Note 5: Turn on the power 1 minute after the AC input is shut down.
5
(13/11/08)