Datasheet
10
PS5R-V Switching Power Supplies
Mounting on DIN Rails
1. Use a 35mm-wide DIN rail.
2. Fasten the DIN rail to a mounting plate using screws.
3. Place the PS5R-V on the DIN rail as shown with input terminal side up
(
), and press the PS5R-V towards the DIN rail (
). Make sure that
the PS5R-V is installed rmly.
4. Use BNL6 mounting clips for fastening the PS5R-V on the DIN rail. Use
of BNL8 mounting clips is recommended when excessive vibration or
shock is anticipated. Do not use the PS5R-V when it is subject to vibra-
tion constantly.
Removal
•Insert a at screwdriver into the slot in the clamp, and pull out the clamp
until it clicks (
). The lock mechanism is released and the PS5R-V can be
removed (
). When mounting the PS5R-V again, push in the latch rst.
Notes for installation
•Do not close the top and bottom openings of the PS5R-V to allow for heat
radiation by convection.
•Maintain a minimum of 10 mm clearance around the PS5R-V, except for
the top and bottom openings.
•When mounting multiple PS5R-V switching power supplies side by side,
maintain a minimum of 10 mm clearance. Observe the derating curves in
consideration of the ambient temperature.
10mm minimum
•When the derating voltage may exceed the recommended value, provide
forced air-cooling.
•Make sure to wire the ground terminal correctly.
•For wiring, use wires of heat resistance of 60C or higher (PS5R-VB: 80C
or higher). Use copper wire of the following sizes, according to the rated
current.
Terminal Wire Size (allowable current) Wire Type
Input AWG18 to 14
Copper
Solid/Stranded
Output
AWG18 to 14
(AWG18: 7A, AWG16: 10A, AWG14: 15A)
Cross-sectional area
AWG18: 0.82mm
2
, AWG16: 1.31mm
2
, AWG14: 2.0mm
2
Note: Wires of the above size must be used to comply with UL508, CSA
C22.2 No. 107.1.
Applicable crimp terminal (reference)
7.0 max.
4.1 max.
5.6 min. (PS5R-VG: 6.3 min)
ø3.6 min.
•Recommended tightening torque of the input and output terminals is 1.0
to 1.3 N·m (0.8 N·m for UL).
Safety Precautions
Operating Instructions
Mount the PS5R-V in an enclosure. Do not use the PS5R-V alone as an
Electric Facilities for General Use.
Use the PS5R-V for electric facilities for business use only.
•Do not use switching power supplies with electric equipment whose malfunc-
tion or inadvertent operation may damage the human body or life directly.
•Make sure that the input voltage and output current do not exceed the ratings.
If the input voltage and output current exceed the ratings, electric shock, re,
or malfunction may occur.
•Do not touch the terminals of the switching power supply while input voltage
is applied, otherwise electric shock may occur.
•Provide the nal product with protection against malfunction or damage that
may be caused by malfunction of the switching power supply.
•Operating temperatures should not exceed the ratings. Be sure to note the
derating characteristics. If the operating temperature exceeds the ratings,
electric shock, re, or malfunction may occur.
•Blown fuses indicate that the internal circuits are damaged. Contact IDEC for
repair. Do not just replace the fuse and reoperate, otherwise electric shock,
re, or malfunction may occur.
•Do not use the switching power supplies to charge rechargeable batteries.
•Do not overload or short-circuit the switching power supply for a long period of
time, otherwise the internal elements may be damaged.
•Do not disassemble, repair, or modify the power supplies, otherwise the high
voltage internal part may cause electric shock, re, or malfunction.
•The fuse inside the PS5R-V switching power supply is for AC input. Use a DC
fuse for DC input.
Mounting Removal
Clamp