4: OPERATION BASICS
4-12 WEB SERVER CPU MODULE USER’S MANUAL FC9Y-B1278
Simulate Operation
Before downloading the user program, you can simulate the operation on the WindLDR screen without connecting the
Web server CPU module.
From the WindLDR menu bar, select
Online > Simulation. The Simulation screen appears.
To change an input status, place the mouse pointer on the input and right-click the mouse. In the pop-up menu, select
Set or Reset to set or reset the input.
To quit simulation, from the WindLDR menu bar, select
Online > Simulation.
Download Program
You can download the user program from WindLDR running on a PC to the Web server CPU module.
From the WindLDR menu bar, select
Online > Download. The Download Dialog appears, then click the OK button. The
user program is downloaded to the Web server CPU module.
Note: When downloading a user program, all values and
selections in the Function Area Settings are also
downloaded to the Web server CPU module.
Note: The Download Dialog is also shown by selecting
Home > Download.