Datasheet
19
A
(When fixed at 90°)
C
D
B
LED Illumination Unit
LF Series Adjustable Angle Mounting Bracket
Mounting angle can be adjusted from 0° to 90°.
LED illumination units can be installed exibly.
•Mountinganglecanbeadjustedfrom0°to90°in10°incre-
ments,providingmoreoptionsformountingoftheLEDillumi-
nationunits.
•Illuminationanglecanbeadjustedtosuittheoperatorinvarious
applications,suchasvisualinspection.
ApplicationExample
LF9Z-1MB1
LF9Z-1MA1
LF9Z-1MDE1
LF9Z-1MDF1
Hexagonal
bolt
Hexagonal
bolt
Adjustable Angle Mounting Bracket
AdjustableAngle
MountingBracketfor
LF1D/LF1B
PartNo. ApplicableLEDIlluminationUnit Material PackageQuantity
LF9Z-1MDE1
LF1D-E/LF1D-EH
StainlessSteel
1pair(rightandleft)
(mountingscrewssupplied)
LF9Z-1MDF1
LF1D-F/LF1D-FH
LF9Z-1MB1
LF1B-NA,-NB,-NC(not-ND,-NE,-NF)
LF9Z-1MA1
LF1A-A,-B,-D
PartNo. E F G
LF9Z-1MDE1
25
±0.2
374
±2.0
4-M5
LF9Z-1MDF1
40
±0.2
292
+4.0
4-M5
LF9Z-1MB1
14
(Note)
4-M4
LF9Z-1MA1
25 (Note) 4-M4
Note:SameasthemountingholecentersofLEDilluminationunits.
–2.0
PartNo. A B C D
LF9Z-1MB1
27.5 35.2 27 50.5
LF9Z-1MA1
55
37.9
33 80
LF9Z-1MB1/1MA1
•UsetheattachedhexagonalboltstoxtheLF1Datthedesiredangle.
•SeespecicationsoftheLF1Dforoperatingenvironmentandmechanicalstrength.
DimensionsforLF9Z-1MA1
Alldimensionsinmm.
Dimensions
28
(73)
90°
53
50 13
36
66
R45
90°
62
36
(87.5)
975
27.5
77
R60
LF9Z-1MDE1 LF9Z-1MDF1
Mounting Hole Layout
4-M5 screws
B
A
Instructions
•LEDmodulesmayvaryinilluminationcolorsandilluminance.
•Beforedesigningequipmentandpoweringupilluminationunits,conrm
thespecicationsdescribedintheinstructionsheet.
•Applyvoltagewithintheratedvalue,otherwisetheLEDelementsmaybe
damaged.
•Theilluminationunitisvulnerabletostaticelectricity.Takesufcient
measureforprotectionagainststaticelectricityandvoltagesurges.
•Makesurethattheilluminationunitdoesnotfallduringtransportation,
installation,andoperation,otherwisedamagemayresult.
•Donotpullorpushthecableoftheilluminationunit,otherwisedamage
mayresult.Allowsufcientslacktothecablewhilewiring.
•Donotapplyexcessiveforce.Donotleaveadamagedilluminationunit
unattendedoruseadamagedilluminationunit.
•Ensurethecorrectoperatingtemperature.Otherwiseinternaltemperature
risemayresultindamage.
•Donotuseorstoreinaplacesubjectedtovibrationandshock.
•Donotuseinthefollowingplaces:
∗Exposedtodirectsunlight,nearheaters,hightemperatures
∗Subjecttochemicals,andcorrosivegases
(Plasticilluminationsurface:Ironpowderandoil)
∗Basements,greenhouses,orotherhumidplaces
∗Coldstoragewarehouses(makesurethatnofreezingoccurs)
•Donotloosenscrews,otherwisetheprotectioncharacteristicswillbe
impaired.
•FortheLF2Dilluminationunits,makesuretoprovidesufcientstrengthfor
mountingpanel.Requiredwaterproofcharacteristicscannotbeobtainedif
adistortedmountingpanelisused.
•Tocleanthecover,useasoftclothwithwaterorneutraldetergent.
Donotusesolventssuchasthinners,benzene,oralkaline,otherwise
discoloration,deterioration,ordecreaseinstrengthmayoccur.
•Theedgeofthecablesheathisnotwaterproofconstruction.Watermay
invadetheLF1Binacapillaryactionwhenwatersplashesdirectlyonto
thecablesheath.
Safety Precautions
•Donotdisassemble,repair,ormodifytheLEDilluminationunit.Otherwise
electricshock,re,ormalfunctionmayoccur.
•Turnoffpowerbeforewiring.Makesureofcorrectwiring,otherwise
electricshockordamagemayresult.
•DonotstaredirectlyintotheLEDilluminationunitwhileitislit,anddonot
projectthelighttootherpeople,otherwiseeyesmaybeinjured.
•LEDilluminationunitisgeneral-purposeindustrialelectricdevice.Do
notuseforelectronicequipmentwhichmaydamagethehumanbodyor
threatenlifeincaseamalfunctionorfailureoccurs.
•EnsurethatthecabledoesnottouchtheLEDilluminationunit.
LF Series LED Illumination Units