Datasheet
6
LD6A LED SignaLight Towers
LD6A LED SignaLight Towers
Oval shape with striped design.
Presents a stylish image on all equipment.
General Specifications
Safety Standards
IEC 60947-5-1, EN60947-5-1, UL508,
CSA C22.2 No.14
Operating Temperature –25 to +55ºC (no freezing)
Operating Humidity 45 to 85% RH (no condensation)
Storage Temperature –40 to +75ºC (no freezing)
Overvoltage Category III (IEC 60664-1)
Impulse Withstand
Voltage
800V (IEC 60947-1)
Insulation Resistance 100 MΩ minimum (500V DC megger)
Dielectric Strength
Between live and dead parts:
1000V AC, 1 minute
Pollution Degree 3
Corrosion Immunity Atmosphere free from corrosive gases
Vibration Resistance
Operating extremes:
10 to 55 Hz, amplitude 0.5 mm
Shock Resistance
Operating extremes:
147 m/s
2
, 6 shocks each in 6 axes
Degree of Protection
(IEC 60529)
Steady: IP65
Steady/ashing/alarm: IP54
Pole mount (w/o L-shaped bracket): IP54
Pole mount (w/L-shaped bracket): IP23
Housing Color Dark gray, Light gray
Material
Housing: ABS resin
Lens: AS resin
Pole: Steel (nickel-chrome plated)
Pole stand: Diecast aluminum
Cable UL1007 AWG22
Functional Specications
Rated Insulation Voltage 60V
Operating Voltage 24V AC/DC ±10%
Rated Voltage (Ue) 24V AC/DC
LED Color Code
R (red), Y (yellow), S (blue),
G (green), W (pure white)
LED
Illumination Color R, Y S, G W
Rated Current
(per tier)
25 mA 30 mA 20 mA
Power Consumption
(per tier)
0.6W 0.75W 0.5W
LED Life (Note)
Approx. 30,000 hours
(until the brightness reduces to 50%
the initial value when lit at complete
direct current of the rated voltage
under 25ºC environment)
Flashing Cycle
(IEC 60073)
Approx. 105 ashes per minute
(1.75 Hz)
Alarm
Alarm Cycle
Alarm 1: approx. 700 times per minute
Alarm 2: approx. 35 times per minute
Draw Current 110 mA max.
Inrush Current AC: 400 mA max. DC: 250 mA max.
Alarm Volume 70 to 90 dB, at 1m (volume adjustable)
Acoustic Frequency Approx. 3.3 kHz
Note: Life of the LED varies according to operating conditions
and environment.
External Contact Ratings
LED
AC Contact Capacity
(per tier)
Current Capacity 100 mA min.
Dielectric Strength 35V AC min.
DC Contact Capacity,
Transistor Capacity
(per tier)
Current Capacity 100 mA min.
Dielectric Strength 35V min.
Leakage Current 0.1 mA max.
Alarm
AC Contact Capacity
(per alarm)
Current Capacity 400 mA min.
Dielectric Strength 35V AC min.
DC Contact Capacity,
Transistor Capacity
(per alarm)
Current Capacity 300 mA min.
Dielectric Strength 35V min.
Leakage Current 0.1 mA max.
Part No. Development
LD6A - 5 W Z Q B - RYSGW C
Function
blank: steady
Z: steady/flashing/alarm
(Note)
Note: Specify illumination color from the top tier.
Number of tiers
1: 1 tier
2: 2 tiers
3: 3 tiers
4: 4 tiers
5: 5 tiers
Mounting style
G: frame mount
W: wall mount
D: direct mount
P: pole mount w/ base
K: pole mount w/L-shaped bracket
Housing color
B: dark gray
W: light gray
Voltage
Q: 24V AC/DC
Lens color
blank: same as LED color
(standard type)
C: transparent
(clear lens type)
LED color code
(specify code from highest tier)
R: red
Y: yellow
S: blue
G: green
W: pure white
• Striped design with non-illuminating area between the lenses.
Built-in super bright LEDs reduce light disturbance to make the
illuminating color stand out.
• IDEC’s unique lens shape enables high-visibility from different
directions.
• Five different mounting styles available. Easy mounting to
aluminum frames, wall mounting, direct mounting, and pole
mounting (with base or with L-shaped bracket).
• Clear lens type available.
• Custom conguration is possible.
• Flashing cycle: 1.75 Hz (approx. 105 ashes per second) Con-
forms to international standard IEC 60073.
• Ergonomically designed alarm sound (3.3 kHz, 2 different
sounds) spreads 360º degrees. Adjustable volume (70 to 90 dB).
• Degree of protection: IP65
(IP54 for steady, ashing, alarm types and pole mount without
L-shaped bracket)
(w/L-shaped bracket)
Frame mount
Direct mount
Pole mount
(w/Base)
Wall mount
Applicable Standards
Mark File No. or Organization
UL508
CSA C22.2 No.14
UL Recognition
File No. E68961
EN60947-5-1 EU Low Voltage Directive