Datasheet

LD6A LED SignaLight Towers
1. When L-shaped bracket is used 2. When L-shaped bracket is not used
The parts marked with * are not supplied and should be prepared
by the user. The screw size depends on the L-shaped bracket
size, as shown below.
When using LD6A-KQ-****** => M10
When using LD6A-KQ1-****** => M8
Replacement/Expansion/Reduction of LED Modules
Make sure to turn power off.
When expanding/reducing the LED modules, make sure
to use the center screw set of the correct length.
Insert a at screwdriver into the recess as shown below,
lift up the cap, and remove the cap with your hands. Use
a at screwdriver with a tip of 1-mm thick and 7-mm
wide maximum.
Remove the center screw before reassembling the LED
modules.
When assembling the LED modules, make sure to align
the recess of the cap with the recess of the LED module.
Otherwise, damage may result.
Recommended tightening torque: 0.4 to 0.5 N·m.
Recess
Recess
Recess
Recess
LED module
Top Cap
Packing
Insert flat screwdriver into recess
1
2
3
Note the correct orientation when assembling the LED modules.
Tighten the screws to the recommended tightening torque.
The LED module may be damaged if the screw is loose dur-
ing operation.
Do not touch the metal plug on the LED module. Other-
wise, LED elements maybe damaged due to static elec-
tricity.
Use a maximum of 5 tiers.
Select an optional screw of an appropriate length de-
pending on the number of tiers.
Do not remove the packing from the LED module. Other-
wise, waterproof characteristics will be impaired.
Hexagonal
nut
(M22)
Hexagonal
bolt
(M10)
Hexagonal
nut
(M10)
Spring washer
Plain washer
Plain washer
Bushing
Hexagonal nut
(M22)
Wiring
For wiring, see the wiring diagrams on pages 9 and 10.
Incorrect wiring may damage the internal circuit.
Be sure to insulate unused wires.
Connect a 1A fuse to the power line as shown in the Wir-
ing Examples on pages 9 and 10.
Use a UL listed external fuse holder.
Use a class 2 power supply only.
When using LED modules of the same color for two or
more tiers, determine contact capacity in consideration of
the LED current, because only one wire is used to light all
tiers of the same color.
Do not apply voltage to ashing (brown) lines.
Do not connect ashing (brown) lines with the power
lines. The internal circuit may be damaged.
Do not turn on steady and ashing lines simultaneously.
Do not turn on alarms 1 and 2 simultaneously.
Wire Color
Wire Color Steady Steady, Flashing, Alarm
Red LED Module – Red LED Module – Red
Orange LED Module – Yellow LED Module – Yellow
Blue LED Module – Blue LED Module – Blue
Green LED Module – Green LED Module – Green
White LED Module – Pure White LED Module – Pure White
Purple Alarm 1
Light Blue Alarm 2
Brown Flashing COM
Gray Power Line
Yellow Power Line Power Line
For information on external contacts, see “External Con-
tact Ratings” on page 6.
Sound Volume Adjustment
Move the sound volume lever to the right and left to ad-
just the sound volume.
The sound volume is at maximum when the lever is set to
the right.
The sound volume adjustment lever may be damaged if
forcibly moved.
Highest Temperature Limitations
The highest temperature is limited to 50ºC when all tiers
are lit continuously in the following combinations:
1. Three tiers
Two or more tiers of blue and green
(example: Red-Green-Blue, Green-Green-Red)
2. Four or ve tiers
(example: Red-Yellow-Green-Pure White,
Red-Yellow-Blue-Green-Pure White)
Max.
Min.
Sound volume
adjustment lever
Benelux B: (+32) 27 25 05 00 - sales@apem.be
NL: (+31) (70) 799 91 51 - sales@apem.be
France (+33) 5 63 93 14 98 - commercial@apem.fr
Germany Munich: (+49) 89 45 99 11 0 - info@apem.de
Hamburg: (+49) 40 253054 0 - info@apem.de
Italy (+39) 0172 74 3170 - apem.italia@apem.it
Sweden (+46) 8 626 38 00 - info@apem.se
United Kingdom (+44) 1 844 202400 - sales@apem.co.uk